Enerco MH170FAVT Operating Instructions, Preparing For Operation, Start, Stop, Servicing

Models: MH170FAVT

1 16
Download 16 pages 48.83 Kb
Page 5
Image 5
OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

PREPARING FOR OPERATION

1.Check the heater for possible shipping damage. If any is found, immediately notify the factory.

2.Follow all of the "Precautions".

3.Connect the POL fitting of hose and regulator assembly to the propane cylinder by rotating the POL nut counterclockwise into the propane cylinder's valve outlet and securely tighten with a wrench.

4.Connect the hose to the heater by rotating the hose fitting clockwise.

5.Securely tighten all gas connections.

6.Open the cylinder's gas valve and check all gas connections with a soap and water solution. DO NOT USE A FLAME.

7.Connect power cord to well-grounded 115V, 60 Hz, 1Ø source of power.

8.When using an extension cord, make certain that it is a 3- wire (grounded) cord of proper wire size.

START

1.Slowly open the main valve at propane cylinder to prevent excess flow check valve from closing.

2.Set thermostat to full on. Heater will ignite automatically.

3.Adjust ball valve on control panel to desired burn rate.

4.Set thermostat to desired temperature. Heater will turn off and on automatically as the temperature varies in the heater area.

STOP

1.Securely close valve on the propane cylinder.

2.Continue to operate heater until all fuel in the hose has burned.

3.Turn the heater thermostat to "off". For extended shut down or in areas where the temperature is below 0°F, unplug the heater.

RESTART AFTER SAFETY SHUTDOWN

1.Securely close valve at propane cylinder. Unplug heater.

2.Wait 5 minutes.

3.Restart following "Start" procedure.

MAINTENANCE AND STORAGE

1.The heater should be inspected before each use, and at least annually by a qualified person.

2.Before each use, check the soft "O" ring seat at the bullnose of the POL fitting. If the "O" ring is cut, scuffed, or otherwise damaged, replace it with part number 6681.

3.Turn off the gas at the LP-gas supply cylinder(s) when the heater is not in use.

4.When the heater is to be stored indoors, the connection between the LP-gas supply cylinder(s) and the heater must be disconnected and the cylinder(s) removed from the heater and stored out of doors and in accordance with Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1, Natural Gas and Propane Installation Code.

SERVICING

A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly:

• The flame is contained within the heater.

The flame is essentially blue with perhaps some yellow tipping.

There is no strong disagreeable odor, eye burning or other physical discomfort.

There is no smoke or soot internal or external to the heater.

There are no unplanned or unexplained shut downs of the heater.

The parts lists and wiring diagram show the heater as it was constructed. Do not use a heater which is different from that shown. In this regard, use only the hose, regulator and cylinder connection fitting (called a POL fitting) supplied with the heater. IMPORTANT Match the color stripe on the hangtag attached to the hose assembly with the color on the label located near the propane inlet fitting on the heater. Do not use alternates. For this heater, the regulator must be set as shown in "specifications". If there is any uncertainty about the regulator setting, have it checked.

A heater which is not working right must be repaired, but only by a trained, experienced service person.

In-warranty products will be repaired with no charge for either parts or labor. Please include a brief statement indicating date, place of purchase, the nature of the problem and proof of purchase.

Out-of-warrranty products will be repaired with a charge for parts and labor.

SIZE AND CAPACITY

OF PROPANE CYLINDERS

The charts below show the approximate size of the cylinder required for these heaters. To use the chart:

1.Select the lowest air temperature expected (at the bottom of the chart).

2.Move straight up to time of operation desired (left side of the chart).

3.Read the cylinder size required.

All heaters should have:

full cylinders

 

good air circulation

 

no frost on cylinders

 

 

 

Fuel Cyclinder Capacity: 100#

 

 

Enerco Group, Inc. Force-Air Propane Construction Heater

5

Operating Instructions and Owner’s Manual

70176 Rev. C 4/07

 

Page 5
Image 5