Enerco MHVFB10LP installation instructions Installing Bottom Mounting Screws

Models: MHVFB10LP

1 16
Download 16 pages 38.15 Kb
Page 7
Image 7

1.Locate two horizontal slots on back pane of heater (see figure 19).

2.Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.

Horizontal Slots

Mounting Bracket mounted to wall

Mounting Screws

Figure 9

Installing Bottom Mounting Screws

1.Locate two bottom mounting screw holes. These holes are near bottom on back panel of heater (see figure 9).

2.Mark screws locations on wall.

3.Remove heater from mounting bracket.

4.If installing bottom mounting screw into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under Attaching to Wall using Anchor. If installing bottom mounting screw into wall stud, drill holes at marked locations using 9/64” drill bit.

5.Re-place heater onto mounting bracket.

6.Place spacers between bottom mounting holes and wall anchor or drilled hole.

7.Hold spacer in place with one hand. With the other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole.

8.Tighten both screws until heater is firmly se- cured to wall. Do not over tighten.

Note: Do not re-place front panel at this time. Re- place front panel after making gas connections and checking for leaks.

CONNECTING TO GAS SUPPLY FOR PERMANENT INSTALLATION

WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.

WARNING: This appliance requires a 3/8” NPT (National Pipe Thread) inlet connection to the pressure regulator.

CAUTION: Never connect heater directly to the Propane supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and Propane/LP supply.

The installer must supply an external regulator. The external regulator will reduce the incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 12. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of larger enough diameter to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Installation must include an equipment shutoff valve, union and plugged 1/8” NPT tap. Locate NPT tap within reach of test gauge hookup. NPT tap must be upstream from heater (see figure 12).

 

 

 

 

 

 

 

 

 

 

 

Pressure

 

 

 

 

 

 

 

 

 

 

 

Regulator

3/8” NPT Pipe Nipple

 

 

 

 

 

 

 

 

Heater

Ground Joint

 

 

 

 

 

 

 

 

Cabinet

 

 

 

 

 

 

 

 

Test Gauge

 

 

Union

 

 

 

 

 

 

 

 

Equipment

 

 

 

 

 

 

 

 

Connection

 

 

 

 

 

Tee Joint

 

Shutoff Valve

 

 

 

 

 

From Gas Meter

 

 

 

 

 

Reducer Bushing

 

 

 

 

 

 

to 1/8” NPT

 

(4” W.C. to 10.5”

 

 

 

 

 

1/8” NPT Plug Tap

 

W.C. Pressure)

 

 

 

 

 

 

 

 

 

 

 

 

 

Tee Joint

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pipe Nipple

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cap

 

 

 

 

 

 

3” Minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sediment

 

 

 

 

Figure 12

 

 

 

 

 

Trap

 

 

 

 

 

 

 

 

 

 

 

 

 

*A CSA/AGA certified equipment shutoff valve with 1/8” NPT tap is an acceptable alternative to test gauge connection. Purchase the CSA/AGA certified equipment shutoff valve from your dealer. See Accessories, page 17.

IMPORTANT: Install an equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater fuel train.

CAUTION: Use pipe joint sealant that is resistant to LP-Gas.

Install sediment trap in supply line as shown in figure 12. Locate sediment trap where it is within reach for clean- ing. A sediment trap traps moisture and contaminants. This keeps them from going into heater. If sediment trap is not installed or is installed improperly, heater may not

7Installation instructions and Owner’s Manual

Page 7
Image 7
Enerco MHVFB10LP Installing Bottom Mounting Screws, Connecting to GAS Supply for Permanent Installation

MHVFB10LP specifications

The Enerco MHVFB10LP is a high-performance propane infrared heater that has made its mark in the heating equipment industry, thanks to its innovative design and advanced technology. Built for both indoor and outdoor use, this versatile heater is particularly popular for its reliability and efficiency in providing warmth in various settings, including garages, workshops, and outdoor gatherings.

One of the standout features of the MHVFB10LP is its high-efficiency infrared heating capability. Unlike conventional heaters that rely on air convection, this unit delivers heat directly to objects and people in its vicinity. This direct heating method not only ensures faster warmth but also reduces energy waste, making it an economical choice for users. With a heating capacity of up to 10,000 BTUs, it can effectively warm spaces up to 250 square feet.

The Enerco MHVFB10LP is equipped with a state-of-the-art Piezo ignition system, which allows for easy and reliable start-up without the need for matches or lighters. Its adjustable heat settings provide flexibility, enabling users to customize their heating experience depending on the specific needs of the environment. Additionally, the heater features a durable construction made from high-quality materials, ensuring longevity and resilience in both indoor and outdoor conditions.

Safety is paramount in the design of the MHVFB10LP. The model includes an integrated safety shut-off system that activates in the event of a tip-over or if the flame goes out, providing peace of mind during use. The heater also features a sturdy base, ensuring stability and reducing the risk of accidental tipping.

Another notable characteristic of the Enerco MHVFB10LP is its compact and portable design. Weighing moderately and featuring a convenient handle, it allows users to easily move the heater wherever needed. This mobility makes it an ideal choice for construction sites, event setups, and home use.

In summary, the Enerco MHVFB10LP stands out for its efficient infrared heating technology, user-friendly features, safety components, and portability. Whether used for work or leisure, this heater is an excellent investment for anyone looking to enjoy warmth and comfort in any environment. With a combination of safety, efficiency, and versatility, the MHVFB10LP delivers exceptional performance that meets the heating needs of various users.