PRODUCT DATASHEET

ENERGIZER E10HH

Specially designed for use in humid climatic conditions.

(top view) (bottom view)

Industry Standard Dimensions

(millimeters)

Asia Pacific Region +852-31026623

Zinc Air

 

Specifications

Chemical System:

Zinc Air (ZnO2)

Tab Color:

Yellow

Designation:

IEC-PR70

Nominal Voltage:

1.4 Volts

Typical Capacity:

91 mAh (to 0.9 volts)

 

(Rated at 3k ohms at 21°C/65% RH)

Typical Weight:

0.32 grams

Typical Volume:

0.08 cubic centimeters

Impedance

3.18

3.00

1.35R Typical

0.015

Typical Coining Depth

5.80

5.60

0.25

Minimum

3.60

3.30

The total opposition that a battery offers to the flow of alternating current. Impedance is a combination of resistance and reactance.

The typical impedance of these cells on open circuit and during useful discharge varies from 5-20 ohms. This applies over a frequency range of 40-5,000 hertz at the current drains shown below.

Impedance vs. Frequency

Typical Discharge Characteristics

Schedule: 16 hours/day

Typical Drain @ 1.3V:

0.43& 0.22 milliamperes Load: 3K & 6K ohms

 

1.4

 

 

 

 

 

 

 

 

 

Voltage

1.3

 

 

 

 

 

 

 

 

 

1.2

 

 

 

 

 

 

 

 

 

1.1

 

 

 

 

 

 

 

 

 

Operating

 

 

 

 

 

 

 

 

 

1.0

 

 

 

 

 

 

 

 

 

0.9

 

 

 

3K

 

 

 

6K

 

0.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

50

100

150

200

250

300

350

400

450

Service, Hours

Simulated Application Test

Typical Performance at 21°C & 50% RH

Schedule:

Typical Drains:

Load

Cutoff

 

at 1.3V

 

0.9V

 

(milliamperes)

(ohms)

(hours)

16 Hours/Day

0.43

3,000

211

16 Hours/Day

0.22

6,000

414

 

35

 

 

 

 

 

 

 

30

 

 

 

 

00% DoD

(ohms)

 

 

 

 

25% DoD

 

 

 

 

 

25

 

 

 

 

50% DoD

20

 

 

 

 

80% DoD

Impedance

 

 

 

 

 

 

15

 

 

 

 

 

 

10

 

 

 

 

 

 

5

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

0.1

1

10

100

1000

10000

100000

 

 

 

Frequency (Hz)

 

 

 

Impedance vs. Depth of Discharge

 

25

 

 

 

 

 

 

 

 

 

 

(ohms)

20

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

Impedance

10

 

 

 

40 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1K Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

Depth of Discharge

Important Notice

This datasheet contains typical information specific to products manufactured at the time of its publication.

©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.

Form No. EBC - 8953AP

Page 1 of 1

Page 1
Image 1
Energizer dimensions Energizer E10HH, Zinc Air