Calibrating the PCU | 11
Calibrating the PCU
After setting up the PCU, follow the steps below to calibrate it. The recommended initial settings for the
PCU are a temperature of 190 °C and a speed of 1.5. To cure properly, the Epson DirectPlate Aluminum
plate should reach an even surface temperature of 150 to 160 °C.
Note:
Depending on the temperature and the altitude where the PCU is located, you may need to adjust these settings
slightly.
Use the included THERMAX temperature strips and run a plate through the PCU with the strips set
across the plate. The THERMAX strips should read between 150 to 160 °C for the plate to be cured
correctly.
1. Turn on the power switch from the rear of the unit. This activates the transport belt.
2. Turn on the Heater switch on the control panel.
Power switch
Set temperature
indicator
Speed control knob
Temperature arrows
Temperature set
button
Current
temperature
indicator
Heater switch