England's Stove Works 24-ICD operation manual Installation & Operation Manual, Revised 1/06

Models: 24-ICD 50-SHW25, 50-TRW25

1 13
Download 13 pages 16.87 Kb
Page 1
Image 1
INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

Thank you for purchasing this product from a fine line of heating equipment.

We wish you many years of safe heating pleasure.

Visit our web site at www.englandsstoveworks.com for helpful information,

frequently asked questions, parts & accessory orders and more.NOTE: IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO THEDEALER. CONTACT CUSTOMER SERVICE @ 1-800-245-6489.

Please note the following Precautionary Statements:

CAUTION: This unit must be installed in accordance with these instructions and must comply with local building and fire codes. Failure to do so could result in a chimney or house fire, property damage, bodily injury or even death.

England’s Stove Works highly recommends the use of smoke detectors and Carbon

Monoxide detectors with any hearth product, including this unit. Follow all manufacturer’s

instructions when using smoke or Carbon Monoxide detectors.

Keep children, furniture, fixtures and all combustibles away from any heating appliance.

Maintain a minimum clearance of thirty inches (30”) from the firebox and eighteen inches (18”) from the flue pipe to any combustible. This can be reduced to six inches (6”) by using a heat shield and double wall or shielded pipe.

This product contains a catalytic combustor, which needs periodic inspection and replacement for proper operation. It is against the law to operate this wood heater with the catalytic combustor removed, deactivated or in a manner inconsistent with the operating instruction in this manual.

Our catalytic stoves are designed to burn seasoned, dry wood.

THIS STOVE IS NOT MOBILE HOME APPROVED.

DO NOT PLACE IN A MOBILE HOME!

24-ICD, 50-SHW25 and 50-TRW25

COMPLIANCE STATUS

Type of Fuel

Wood

Emission Rate

2.4 Grams/Hour

Tested Overall Efficiency

83.78%

EPA Certificate Number

443

This unit is certified to EPA phase II standards.

Revised 1/06

Page 1
Image 1
England's Stove Works operation manual Installation & Operation Manual, Revised 1/06, 24-ICD, 50-SHW25 and 50-TRW25