Figure 4: Thermostat Switch in
MANUAL poition.
Figure 5: Thermostat Switch in
HIGH/LOW poition.
  


 

 
1
2
3
4
5
6
7
8
9
  


 

 
  


 

 
1
2
3
4
5
6
7
8
9
  


 

 
8
Figure 6: Thermostat Switch in ON/
OFF poition.
  


 

 
1
2
3
4
5
6
7
8
9
  


 

 
Operating Instructions
OPERATING YOUR PELLET STOVE:
PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed properly
against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit.
DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.
Note: The thermostat mode can be changed during normal operation.
MANUAL MODE:
All control of circuit board function is adjusted at the circuit board.
To START: Press the ON / OFF button. The stove will turn on. The
system light will flash. The Auger Light will flash with each pulse of
the auger (the Auger Feed Rate is pre-programmed during start-up).
The Heat Level Indicator will show the Heat Level that the stove will
run at after start-up.
If this is the first time the unit has been started or the unit has run out of fuel, the auger will need to
be primed. Press the Manual Auger Feed button until fuel starts to drop into the Burn Pot Liner (see
OPERATING INSTRUCTIONS; CONTROL BOARD FUNCTIONS”).
To OPERATE: When a fire has been established, the System Light will turn solid (after approximately 10
- 15 minutes) and the Auger Light will continue to flash to the corresponding Heat Level setting. The Heat
Level button can now be pressed at this time to change the desired Heat Level Output setting.
The convection blower (room air blower) will turn on. The speed of this blower is controlled by the setting
of the heat level output indicator. The convection blower can be turned OFF by depressing the convection
blower control button. For the best efficiency and to prevent cycling, the convection blower should be
left on at all times.
When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different
quality fuels. These settings can be used if the fire keeps going out on low (poor quality fuel). Or if the
low setting is too hot for the room (see “OPERATING INSTRUCTIONS; CONTROL BOARD FUNCTIONS”).
HIGH/LOW MODE: (Requires a thermostat)
INITIAL START-UP: See manual mode above.
OPERATION: When the thermostat calls for heat (contacts are
closed) the stove settings are adjustable as per Manual Mode. When
the thermostat contacts open, the HEAT LEVEL and Fans will drop
down to the LOW setting until the thermostat contacts close again.
*The LOW heat setting can be adjusted for different fuel qualities
(see “OPERATING INSTRUCTIONS - CONTROL BOARD FUNCTIONS”). The stove will come back to the previous HEAT
LEVEL setting when the thermostat contacts close again.
AUTO/OFF MODE: (Requires a thermostat)
INITIAL START-UP: See manual mode above.
OPERATION: When the thermostat contacts close, the unit will
light automatically. Once up to temperature, the stove operates the
same as in MANUAL. When the thermostat contacts open, the stove’s