8
This is used to regulate the airflow through the pellet
stove.
• On the low heat output settings, push the slider all the
way in.
• On the high heat output pull the slider out or until a good
fire is achieved. A good fire is in between a fire with lazy
black tipped flames and a forced fire (very quick, shorter
flames). A good fire is the most efficient and will have a
bright and active flame.
• Slider should be set at a hot magnehelic reading of 0.14”
W.C. (34 Pa) for firebox vacuum.
5. The convection blower (room air blower) will be on, the speed of this blower is controlled by the
setting set on the heat output indicator. The convection blower can be turned OFF by depressing
the convection blower control button. It is recommended that the convection blower be left on at all
times.
6. When unit is operating on LOW the unit can be adjusted for poorer quality fuels. By depressing the
Auger Trim button, WHEN THE UNIT IS ON LOW, the ON time the auger pulses can be changed from
2 seconds ON to 4 seconds ON.
AUGERTRIM
AUGERTRIM
AUGERTRIM
2 SECONDS
“ON”
3 SECONDS
“ON” Factory
Setting
4 SECONDS
“ON”
Operating Instructions

TURNING OFF YOUR PELLET STOVE:

To turn the unit OFF, simply press the ON / OFF button. All LED lights will go out. This will stop the feed
of pellets. The blowers will continue to operate and cool the stove. When cool enough, the stove will shut
down.
NOTE: During the 15 minute start-up sequence the stove can not be turned off by turning the water
temperature dial down. If the dial is turned down, the stove will run through its complete start-up
sequence and shut down after the stove has lit. The unit can be shut-off manually at this time by pressing
the ON/OFF button.

SLIDER/DAMPER OPERATION:

Figure 4
����
���
�������
Figure 5

These settings can be used if the unit does not

keep a fire going on low (poor quality fuel).

These settings could also be used if the low

setting is too hot or cold for the surrounding

area.

7. Set water and/or room thermostats to desired

temperature(s).