Freestanding Direct
Vent Kit With Coupler
Please read and understand these instructions before installing. Failure to follow these instructions carefully could cause property damage or personal injury.
KIT COMPONENTS:
Quantity | Description | Quantity | Description |
|
|
|
|
1 | Horizontal direct vent termination cap | 1 | Ø65⁄8” (17 cm) 90° elbow |
|
|
|
|
2 | Flue collar adapters (only one used) | 4 | Wire spacers |
|
|
|
|
4 | 3 | Decorative rings | |
|
|
|
|
1 | Wall thimble | 1 | 4 oz tube RTV silicone |
|
|
|
|
1 | Inside finish trim collar | 20 | 9/16” tech screws |
1 | 5’ (190 cm) length of Ø4” (10 cm) double walled flex pipe | 8 | 11⁄2” wood screws |
|
|
|
|
2 | 24” (61 cm) section of Ø65⁄8” (17 cm) straight pipe | 1 | Vinyl siding deflector |
|
|
|
|
Please ensure that all components are supplied with this kit. If components are missing or have been damaged, contact your dealer, distributor, or courier company. Do not attempt the installation if components are missing or damaged.
INSTALLATION INSTRUCTIONS:
1.Decide on a location for the unit that will meet any or all local code requirements. Refer to the sections in your owner’s manual on where to locating your stove, planning your installation and clearances to combustibles.
2.Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing pipes are in the way of the venting system as it passes through the wall. If obstructions are found in the wall it may be required to adjust the location of the appliance.
3.Set the appliance in the desired location. Temporarily place a 24” (61 cm) section with the
4.Install the 90° elbow onto the vertical pipe on the stove pointing in the direction that the vent will exit the structure.
5.Project a level line from the center point of the elbow. Using this center point, scribe a 10” (25.4 cm) hole or square on the wall . Cut the hole out on both the interior and exterior wall surface.
6.Frame the hole as shown in Figure 1.
7.Install the wall thimble and secure the thimble to the inner wall surface.
8.With the appliance still in place install the 24” (61 cm) horizontal section on the elbow and let this section of pipe protrude through the exterior surface. Mark the pipe so that when it is cut it will be flush with the exterior wall.
9.Dismantle the outer pipe sections.
��� |
������� |
��� |
������� |
Figure 1 |