DECIDING WHERE TO LOCATE YOUR STOVE

DIMENSIONS:

Front Width:

36 5/8”/ 93 cm

Rear Width:

36 5/8”/ 93 cm

Height:

 

32 1/4”/ 82 cm

Depth

13 11/16”/ 34.77 cm

Shipping Weight: 132 lbs/59.9 kg

CLEARANCES:

A. Side wall to stove

2”/

5 cm

B. Rear wall to stove

1”/ 2.5 cm

C. Floor to stove

0”/

0 cm

D. Corner clearance

1”/ 2.5 cm

Maintain sufficient clearances for service and maintenance

The stove should be located out of traffic and away from furniture and draperies.

The stove should have sufficient access for its safe operation and maintenance.

Locate a position where the flue system of the stove can be properly installed without damaging the integrity of the building. e.g. cutting a wall or ceiling joist.

The stove can be installed on any wood or concrete surface.

Check stove and flue system clearance requirements.

Locate the stove where it can be accessed by a gas supply line.

Locate the stove in a large and open room that is centrally located in the house. This will optimize heat circulation and comfort.

As the stove could be equipped with a convection fan, ensure that an electrical source is supplied to the chase that the unit has been installed.

These stoves can be installed in bedrooms.

(IN CANADA: must be installed with a listed wall thermostat)

(IN USA: see current ANSI Z223.1 for installation instructions.)

The flow of combustion and ventilation air must not be obstructed.

MOBILE HOME

When the unit is installed in a Mobile Home it must be grounded to the steel chassis or connected to a grounding rod.

In a Mobile Home installation the unit must be bolted securely to the floor using the holes provided. Manufactured (mobile) home installation must be in accordance with the Manufactured Home Construction and Safety Standard, UL 307B, Title 24 CFR, Part 3280 and/or The Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A

4

Page 4
Image 4
Enviro EG 33 owner manual Deciding Where to Locate Your Stove, Mobile Home, Dimensions, Clearances