Address Data Data Format Default
1EH Reserved 0000H
1FH Pitch direction
setting 0: Bi-d, 1: Uni-d 00H
20H I/F modeselection 0: Auto I/FSelection, 1: Parallel I/F, 2:Type-B
I/F 00H
(Auto)
21H Auto I/Fwait time
setting 10: 10 Sec., 30: 30 Sec., 00: 10 Sec. 0AH
(10 sec.)
22H Auto line feed
Auto tear off
Skip over
perforation
High speed draft
Input buffer
———
———
———
b0: Auto line feed 0: Off 1:On
b1: Auto tear off 0: Off 1:On
b2: Skip over perforation 0: Off 1: On
b3: High speeddraft 0:On 1: Off
b4: Input buffer 0: On 1:Off
b5: Reserved
b6: Reserved
b7: Reserved)
00H
23H Software
0 slashed
Buzzer
——
Auto CR
——-
——-
——-
b0: Software 0: ESC/P 1:IBM2381 Plus
b1: 0 slashed 0:Off 1: On
b2: Buzzer 0: On 1: Off
b3: Reserved
b4: Auto CR (IBM) 0: Off 1: On
b5: Reserved
b6: Reserved
b7: Reserved
00H
24H, 25H Tear Off
adjustment –128 to +127(in units of 1/432 inch) 0000H
26H Reserved 00H
27H Backup flags 1
Copy mode 00H
28H Backup flags 2
In tear-off state
Bin select
b0: Friction Bin 1 or Tractor not Tear Off
b1: Friction Bin 1
b2: Friction Bin 2
b3: Friction (Card Stock)
b4: Tractor and Tear off
00H
29H Panel mask
pattern 1 b0: LOAD function
b1: EJECT function
b2: FONT selection
b3: PITCH selection
b4: TEAR OFFfunction
b5: BIN selection
b6: Draft self test
b7: LQ self test
00H
2AH Panel mask
pattern 2 b0: LF function
b1: FF function
b2: MICRO ADJUSTfunction
b3: PAUSE function
b4: Data dump
b5: Default setting
b6: Bi-d adjustment
b7: Reserved
00H
Assignmentof data for two or morebytes is sequential: from lowerbyte to loweraddress, and
from higher byteto higher address.
FX-2170 Service Manual Appendix
Rev. A A-3