Address Data Data Format Default
2BH Manual feed wait
time 3 to 30(in units of 0.1 sec.), 00H: 0.3 sec.
(same as default) 03H
(0.3 sec.)
2CH 1 Tear-off wait time 3 to 30(in units of 0.1 sec.) , 00H: 0.3 sec.
(same as default) 03H
(0.3 sec.)
2DH, 2EH Reserved 00H
2FH, 33H Reserved 00H
34H, 53H Reserved 00H
54H, 5DH Reserved 00H
5EH, 5FH Paper edge length 00H
60H, 61H Paper length for
rear manual insertion 1 to 22x 432 (in units of 1/432inch 0000H:
22 inches (same as default) 2520H
(22")
62H, 63H Paper length for
front manual
insertion
1 to 22x 432 (in units of 1/432inch 0000H:
22 inches (same as default) 2520H
(22")
64H to66H Sub number for
customization 00H to 09H 000000H
Standard
67H Reserved 00H
Area 2
68H Market 0: Standard version, 1: NLSPversion 00H
69H to 70H Reserved 00H
71H Checksum of Area 2
(68-70H) 00H
Area 3
72H Vp adjustment value 80H
73H Vp adjustment
value(complement
of 72H)
7FH
74H Bi-d adjustment
value for highspeed
draft mode
–12 to +12 (in units of 1/720 inch) 00H
75 H Bi-d adjustment
value for draft mode –12 to +12 (in units of 1/720 inch) 00H
76H Bi-d adjustment
value for LQ mode –12 to +12 (in units of 1/720 inch) 00H
77H Reserved 00H
78H TPE level FFH
79H TPE adjustment
position –10 to +10 (in units of 1/216 inch) 00H
7AH to 7EH Reserved 00H
7FH Reserved 00H
❇EEPROM datain Area 3 is set for eachprinter in thefactory. Do not change this dataafterwards.
Appendix FX-2170 Service Manual
A-4 Rev.A