General Description STYLUS 800 Service Manual
1.4.2 Panel Operation at Power On
The following functions can be activated at power on by holding down the specified button on the
control panel.
Self-test mode:
Start the self-test printing mode by turning the printer on while
holding down the FONT button.
Hex dump mode:
Start the built-in hexadecimal data dump print mode by returning
the printer on while holding down the FONT and LOAD/EJECT
buttons. Once this mode is selected, the printer prints all received
print data in hexadecimal form.
Demonstration mode:
Start printing of a demonstration page by returning on the printer
while holding down the ALT button.
Other functions that can be activated with the control panel at power on, such as the default setting
mode and the initial ink charge mode, are described in the sections that follow.
1.4.3 Default Setting
The printer can memorize certain number of printer setting parameters that defines its functions at
the initialization. You can change these parameters with the default setting mode for your specific
preference of the printer setting.
1.4.3.1 Default Setting Item
The settings listed in the table below can be made with the default setting mode. The default-setting
mode can be activated
by
hold down
the
ECONOMY/CONDENSED button while turning on the
printer. (Refer to the
use~’s
guide for the detail operation of the default-setting mode.)
Table 1-7. Default Setting Item
Menu Description
Facto~
Contents
Setting
Character Table
Select the character table
ON: Print direction is automatically selected as to maintains
Auto Print Direction optimal print quality (alignment).
ON
OFF: Depends on the command ‘ESC U’.
ON: For network environment, such as LocalTalk.
Network l/F Mode
(Time-out printing is disabled.)
OFF
ON: For normal environment.
(llme-out
printing is enabled.)
ON: To ensure proper printing of the image containing
Mixed Text/Graphics
graphics and scalable font, with certain applications,
Mode
OFF
such as MS Word, WordPerfect
V.5. I
or earlier.
1
OFF: For normal use.
ON: Line feed operation is automatically performed by CR
Auto Line Feed
code input.
OFF
OFF:NO line feed operation with single CR code.
.
.
.
.
.
f
Note:
*1= If set to ON, the capacity of input buffer is limited to 8
Kbyte,