ESC/VP21 Commands

Command List

When the power ON command is transmitted to the projector, the power
turns on and it enters warm-up mode. When the projector's power has
turned on, a colon ":" (3Ah) is returned.
When a command is input, the projector executes the command and
returns a ":", and then accepts the next command.
If the command being processed terminates due to a problem, an error
message is output and a ":" is returned.
* Add a Carriage Return (CR) code (0Dh) to the end of each command and
transmit.

Communications protocol

Item Command
Power ON/OFF ON PWR ON
OFF PWR OFF
Signal selection Video SOURCE 41
S-Video SOURCE 42
A/V Mute ON/OFF ON MUTE ON
OFF MUTE OFF
A/V Mute selection Black MSEL 00
Blue MSEL 01
Logo MSEL 02
Item Command
Computer1
Port Computer2
Port
Signal selection Computer (Auto) SOURCE 1F SOURCE 2F
Computer SOURCE 11 SOURCE 21
Component Video SOURCE 14 SOURCE 24
• Default baud rate setting: 9600 bps
• Data length: 8 bits
• Parity: None
• Stop-bit: 1 bit
• Flow control: None
• Connector shape: D-Sub 9-pin (male)
• Projector input connector: RS-232C