EPSON Perfection 636

Digital halftoning AAS (Auto Area Segmentation, enable/ disable selectable)

3 halftoning modes (A, B, and C) and

4 dither patterns (A, B, C, and D) for bi-level and quad-level data

Gamma correction 2 types for CRT display 3 types for printer

1 type for user-defined

Color correction

1 type for CRT display

 

3 types for printer output (available in

 

color byte sequence mode and color line

 

sequence mode)

 

 

1 type for user-defined

Interfaces

Two SCSI (half pitch 50-pin connectors)

Light source

White cold cathode fluorescent lamp

Reliability

30,000 cycles of carriage movements

 

(main unit MCBF)

 

Dimensions

Width: 11.3 inches (287 mm)

 

Depth: 16.7 inches (425 mm)

 

Height: 3.4 inches (88 mm)

Weight

Approx. 9.9 lb (4.5 kg)

Electrical

 

 

 

 

 

 

 

Specification

 

100120 V model

220240 V model

 

 

 

 

Input voltage range

 

AC 90 to 132 V

AC 198 to 264 V ± 10%

 

 

 

 

Rated frequency

 

50 to 60 Hz

 

 

 

 

 

Input frequency

 

49.5 to 60.5 Hz

 

 

 

 

 

Rated current

 

0.5 A

0.3 A

 

 

 

 

Power consumption

 

Approx. 20 W

 

 

 

 

 

Check the label on the back of the scanner for voltage information.

Environmental

Temperature

Operation

 

41 to 95

°F (5 to 35 °C)

 

50 to 89

°F (10 to 32 °C) when using the

 

auto document feeder

 

Storage

 

 

–13 to 140 °F (–25 to 60 °C)

Humidity (without

condensation) Operation 10% to 80%

20% to 80%, when using the auto document feeder

Storage

10% to 85%

Operating

conditions Ordinary office or home conditions; avoid extreme dust, direct sunlight, and strong light. Make sure the outlet provides enough power.

Safety Approvals
120 V model

 

 

Safety standards

UL 1950 with D3

 

CSA C22.2 No. 950

 

EMI

FCC part 15 subpart B class B

 

 

CSA C108.8 class B

230 V model

 

 

Safety standards

EN 60950

 

EMC

EN 55022 (CISPR Pub 22) class B

 

 

AS/NZS 3548 class B

CE marking

 

 

230 V model

Low Voltage Directive 73/23/EECEN

 

60950

 

 

EMC Directive 89/336/EECEN 55022

 

Class B

 

 

EN 61000-3-2

 

EN 61000-3-3

 

EN 50082-1

 

 

IEC 801-2

 

 

IEC 801-3

 

 

IEC 801-4

SCSI Interface

 

Interface type

ANSI X3T9.2/375R Revision 10L

 

(SCSI-2)

Functions

BUS FREE phase

 

ARBITRATION phase

SELECTION/RESELECTION phase COMMAND phase

(the Logical Unit Number is fixed to 0 and the command link function

is not supported) DATA phase

Data in phase Data out phase

STATUS phase MESSAGE phase

MESSAGE IN phase MESSAGE OUT phase

ATTENTION condition RESET condition

2 - EPSON Perfection 636

10/98