Anchoring Ceiling Plate
4 |
| Cut tie wire (G) into four pieces of equal length. Insert wires through ends of turnbuckles and loop. Twist each wire | ||
| around itself at least six times. |
| ||
|
| Drill holes for four ceiling anchors (see "Various Anchoring Methods"). Position the holes so that when the tie | ||
|
| wires (G) are attached and taut will angle out at 15O. | ||
|
| Pull tie wires tight and loop though turnbuckles of the ceiling anchors (or truss). Again twist each wire around itself | ||
|
| at least six times. |
| |
|
| When this step is complete, the weight of the ceiling tray should be supported by the tie wires. | ||
|
| NOTE: 20' (6.1 m) of tie wire (G) is provided. If space between the true ceiling and suspended ceiling is more than | ||
|
| 36" (914 mm), additional wire (12 gauge annealed, steel, black) will be needed. | ||
|
|
|
|
|
|
|
|
| VARIOUS ANCHORING METHODS |
| Wood Joists or Beams | Solid Concrete | ||
| Drill 5/32" (4mm) dia. | Drill 1/4" (6 mm) dia. holes 1.5" (38 mm) | ||
| holes 2" (51mm) deep. | deep. Hammer in Concrete Anchor (I) | ||
| Fully insert eye bolts (H). | using Rawl #3250 setting tool | ||
|
|
|
| or equivalent. |
|
|
|
|
|
|
| Truss Ceiling |
|
| No anchor required. After |
|
| attaching tie wire to turnbuckle |
|
| loop upper end around ceiling |
H | I | truss. Pull tie wire tight and |
twist it around itself at least six | ||
|
| times. |
WARNING
•It is the responsibility of the installer to verify that the ceiling to which the suspended ceiling kit is anchored will safely support four times the combined weight of all attached components (Projector Mount, Extension Column, etc.) and equipment.
5 | Suspended Ceiling Kit installation is now complete. |
After all components (Projector Mount, Extension |
Column, etc.) and equipment have been attached, tension the tie wires by adjusting turnbuckles (F).
NOTE: Load must be carried by tie wires - not suspended ceiling runners.
G | G | 15° |
|
G
A
2"
CEILING | |
PROVIDED FOR | |
RUNNER | ELECTRICAL OUTLET |
1.5" | BOXES ANDANTENNA |
| LEADS. |
DETAIL 2
5 of 6 | ISSUED: |