ESC/VP Level 6 Serial Communication Manual (Abridged Edition)

6. CONTROL CODE

00 SPECIAL CONTROL

Command

 

 

 

Apply

 

 

 

 

 

 

Reply

 

 

 

structure

STX

Size

Attribu

From

Group

Item

Param

Check-

STX

Size

Attribu

From

Group

Item

Param

Check-

 

Type

te

To

eter

sum

te

To

 

eter

sum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03 : Power

Controls the projector power and gets the present power state.

<In the case of a power on setup of EMP-7600/5600>

Set

1B

07

01

--

00

03

01

F4

1B

06

81

--

00

03

--

CS

C1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<In cases other than a power on setup of EMP-7600/5600, and the case of EMP-8100/9100/8150/7700>

[Parameter] Data relating to the power states.

 

0x00: PowerOFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x01: PowerON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x02: Suspend

 

}

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x10: During Startup

* Although setting 0x02 and later in parameter and sending command to the projector, returns NG

 

0x11: Cool down

 

in replay. 0x02 and later are available just for informing from the projector.

 

 

 

 

0x20: System fault

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1D

0009

 

01

01

00

03

00

CS

1D

0008

81

10

00

 

03

--

CS

 

01

000A

C1

 

PARA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Get

1D

0008

 

02

01

00

03

--

CS

1D

0009

82

10

00

 

03

PARA

CS

 

000A

C2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

06 : Communication rate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controls the communication rate.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Parameter] Data relating to communication rate.

 

 

 

 

 

 

 

 

 

 

 

 

 

<For EMP-8100/9100/8150/7700>

 

<For EMP-7600/5600>

 

 

 

 

 

 

 

 

 

0x00: 9600bps

 

 

 

 

0x00: 9600bps

 

 

 

 

 

 

 

 

 

 

0x01: 19200bps

 

 

 

 

0x01: 19200bps

 

 

 

 

 

 

 

 

 

 

0x02: 38400bps

 

 

 

 

0x02: 38400bps

 

 

 

 

 

 

 

 

 

 

0x03: 57600bps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1D

0009

 

01

01

00

06

PARA

CS

1D

0008

81

10

00

 

06

--

CS

 

000A

C1

 

PARA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Get

1D

0008

 

02

01

00

06

--

CS

1D

0009

82

10

00

 

06

PARA

CS

 

000A

C2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Initialize

1D

0008

 

03

01

00

06

--

CS

1D

0009

83

10

00

 

06

PARA

CS

 

000A

C3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09 : Lamp Hour

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gets the present lamp hour.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Parameter] Returns the present lamp hour (in hours) (2 bytes)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Get

1D

0008

 

02

01

00

09

--

CS

1D

000A

82

10

00

 

09

PARA

CS

 

000A

C2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 : Error information

Gets and reports projector error information.

[Parameter] Projector error information

The following data is set with an OR: 0x00: No error or error is cancelled.

0x01: Fan problem

0x04: Internal temperature is abnormally high.

0x08: Lamp life expectancy is closed to end.

0x20: Lamp problem

0x40: Other failures

0x80: Stack failure (EMP-8100/8150/9100 only)

Set

1D

0009

01

01

00

12

--

CS

1D

0008

81

10

00

12

--

CS

000A

C1

PARA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Get

1D

0008

02

01

00

12

--

CS

1D

0009

82

10

00

12

PARA

CS

000A

C2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9 of 20