49
R4C624
short.bk Rev_C
A5 size MAINT.FM
6/15/00 Pass 0
R
Proof Sign-off:
M.Otsuka, CRE M.Moriyama_______
N.Nomoto _______
editor name _______
3. When the
Ppower light stops flashing, print a nozzle check
pattern to confirm that the head is clean and to reset the
cleaning cycle.
If print quality hasn’t improved after repeat ing this procedure
four or five times, turn the printer off and leave it alone overnight.
Then do the head cleaning again.
If the print quality still has not improved, one or both of your ink
cartridges may be old or damaged and may need to be replaced.
To replace an ink cartridge before it is empty, see “Replacing Ink
Cartridges” in the online Reference Guide.
If print quality remains a problem after replacing the ink
cartridges, contact your dealer.
Note:
To maintain print quality, we recommend turning on the printer for at
least one minute every month.
Aligning the Print Head
If you notice a misalignm ent of verti cal lines, yo u may be able to
solve this problem using the Print Head Alignment utility in your
printer software. Follow the directions in the appropriate section
below.
Note:
Do not start the Print Head Alignment utility while printing is in
progress; otherwise, your printout may be marred.
For Windows users
1. Make sure A4 or Letter size Archival Matte Paper is loaded
in the sheet feeder.
2. Click the Utility tab in the printer software, then click the Print
Head Alignment button.