Ergotron 888-122 manual StyleView Vertical Lift, PATIENT ROOM

Models: 888-122

1 9
Download 9 pages 45.59 Kb
Page 1
Image 1
StyleView® Vertical Lift, PATIENT ROOM

StyleView® Vertical Lift, PATIENT ROOM

User's Guide

WARNING: Because surfaces vary widely and the

ultimate mounting method is out of Ergotron’s control,

it is imperative that you consult with appropriate

engineering, architectural or construction professional to ensure that your Ergotron mounting solution is mounted properly to handle applied loads.

CAUTION: Do Not remove cardboard spacer until instructed to do so.

 

A

B

C

D

E

F

G

H

I

J

 

 

 

 

 

 

 

 

 

 

 

1

1x

 

 

 

1x

 

1x

 

 

 

 

1x

 

 

 

 

 

 

 

 

198.755

53.023

22.543

 

 

 

 

 

 

 

 

 

7.825

2.088

.888

2

 

1x

 

 

1x

 

H

MOUNTING HEIGHT LINE:

 

12.700

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(OBTAINED BY SOLVING

4X Ø

.500

 

 

1x

2x

1x

1x 1x

1x

1x

EQUATION BELOW)

PILOT HOLE

 

 

2x

SCREW PATTERN

 

X

 

 

 

 

 

 

MOUNTING HEIGHT EQUATION FOR STANDING

 

 

 

 

 

 

 

APPLICATIONS:

 

 

 

 

 

 

 

67.50 (1715MM) - X = H

 

 

 

 

 

 

 

X = DISTANCE FROM THE TOP OF THE MONITOR

 

 

 

 

 

 

 

 

 

 

SCREEN TO THE CENTER OF THE MOUNTING

 

 

3

 

 

 

 

 

 

 

H = HEIGHT FROM FLOOR TO MOUNTING HEIGHT

 

 

 

 

 

 

 

 

 

LINE (ABOVE)

 

 

 

 

 

 

 

 

 

 

1. REFER TO THE MANUAL.

 

 

 

 

 

 

 

 

 

 

2. MEASURE THE DISTANCE FROM THE TOP OF THE MONITOR

 

 

 

 

 

 

 

 

 

SCREEN TO THE CENTER OF THE MOUNTING SCREW PATTERN.

 

 

 

 

 

 

 

 

 

3. DETERMINE ERGONOMICLLY CORRECT VIEWING HEIGHT BY

 

 

 

 

 

 

 

 

 

 

USING EQUATION ABOVE (OR BELOW).

 

 

 

 

 

 

 

 

 

 

4. MARK THE DETERMINED VALUE FOR H, ON THE WALL.

 

 

 

 

 

 

 

 

 

 

5. ALIGN MOUNTING HEIGHT LINE TO MARK ON THE WALL.

 

 

 

 

 

 

 

 

 

 

USING A LEVEL, LEVEL THE TEMPLATE, THEN TACK IN PLACE.

 

 

 

 

 

 

 

 

 

 

6. CLEARLY MARK THE POSITIONS FOR FOUR PILOT HOLES

 

 

 

 

 

 

 

 

 

 

INTO THE WALL.

 

 

 

 

 

 

 

 

 

 

 

7. DRILL THE FOUR PILOT HOLES.

 

 

 

 

 

 

 

 

 

 

765.175

 

 

 

704.850

 

 

 

 

 

 

 

 

 

 

27.750

 

 

 

 

 

 

 

30.125

 

 

 

 

 

2x

 

 

 

 

 

 

MOUNTING HEIGHT EQUATION FOR SITTING

 

 

4

 

 

 

 

 

 

APPLICATIONS:

 

 

 

 

 

 

 

 

52.00 (1321MM) - X = H

 

 

 

 

 

 

 

 

X = DISTANCE FROM THE TOP OF THE MONITOR

 

 

 

 

 

 

 

 

SCREEN TO THE CENTER OF THE MOUNTING

 

 

 

 

 

 

 

 

SCREW PATTERN (SEE PICTORIAL)

 

 

 

 

 

 

 

 

 

 

H = HEIGHT FROM FLOOR TO MOUNTING HEIGHT

 

 

 

 

 

 

 

 

 

 

LINE (ABOVE)

 

 

 

5

1x

 

1x

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTLINE OF 9"

 

 

 

 

 

 

 

 

 

 

 

VERTICAL LIFT SYSTEM

 

 

 

 

 

3/16"

3/32"

 

 

 

 

 

PILOT HOLE

 

 

 

1x

 

1x

 

 

 

 

 

 

 

ERGOTrON

 

 

 

 

 

 

 

 

304.800

 

 

 

 

 

 

 

 

 

 

 

12.000

 

6

 

 

2.5mm

 

 

 

 

 

 

 

 

 

5/32"

 

 

 

 

 

 

 

 

4x

 

 

 

4x

 

1x

 

 

5x

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

1/4-20 x 1-1/2"

 

 

 

 

 

 

 

 

4x

4x

 

4x M4 x 20mm 4x

4x

 

 

12x

 

8

 

 

 

 

 

 

 

 

 

 

 

8-32 x 1/4"

M4 x 10mm

 

 

 

 

M4 x 10mm

 

 

M4 x 6mm

1/2"

1/2"

1/2"

Ø 1/2" (12.8 mm) Manual backgroundManual background

2 Manual backgroundManual background1

888-60-503-G-00 rev. B • 07/08

1/9

Page 1
Image 1
Ergotron 888-122 manual StyleView Vertical Lift, PATIENT ROOM