Ericsson EDA manual Remote Site Elements

Models: EDA

1 14
Download 14 pages 27.83 Kb
Page 10
Image 10

The Remote Site

4 The Remote Site

The Remote site is the extension of the EDA network. The Shared DSL solution does not specify the full extent of the site, only the minimum required functionality and basic elements.

4.1Remote Site Elements

The remote site must contain at least the following elements:

-48 VDC power supply

230 VAC outlet

CPE modem

EPN102 EDA Power Node

IP DSLAM

Necessary KRONE connectors for the IP DSLAM and EPN102

Depending on the type of installation and IP DSLAM used, an EDA filter might also be necessary.

Note: Under usual circumstances, it is not necessary to have a battery backup of the system, since the remote site is supplied with the same power as the rest of the building.

6

1/1553-HSC 901 86/1 Uen A 2006-02-21

Page 10
Image 10
Ericsson EDA manual Remote Site Elements