Ericsson LBI-38756 manual LBI-38652, General, Transmitter, Receiver

Models: LBI-38756

1 10
Download 10 pages 58 Kb
Page 2
Image 2
LBI-38652

LBI-38652

LBI-38652

 

 

TABLE OF CONTENTS

 

 

Page

SPECIFICATIONS

1

PACKAGE NUMBERS

2

OPTIONS

2

INTRODUCTION

2

RADIO DESCRIPTION

2

MAIN BOARD ASSEMBLY

2

FRONT PANEL ASSEMBLY

4

POWER AMPLIFIER ASSEMBLY

4

FEATURES

4

PC PROGRAMMABLE

4

EXTERNAL SPEAKER (Optional)

5

BATTERY POWER

5

EASY ACCESSIBILITY

5

SERVICE AIDS

5

DETAILED TYPE 99 OPERATION AND PROGRAMMING

5

GE TYPE 99 FORMAT

6

MOTOROLA FORMAT

6

MECHANICAL PARTS BREAKDOWN

8

MECHANICAL PARTS LIST

9

FIGURES

 

Figure 1 - MDS Conventional Radio Block Diagram

3

TABLES

 

Table 1 - Channel Guard Tone Frequencies

5

Table 2 - Primary and Equivalent Digital Codes (OCTAL)

5

Table 3 - Tone Groups

6

Table 4 - Tone Generator Frequencies

6

Table 5 - Motorola Type Coder Numbers

6

Table 6 - Motorola Group Call Tone Groups (TG)

7

Table 7 - Motorola Group Call Tone Groups (TG)

7

Copyright © April 1992, Ericsson GE Mobile Communications, Inc.

 

SPECIFICATIONS

GENERAL

 

 

Frequency Range

Transmit:

148-174 MHz

 

Receive: Same as Transmit

Channel Spacing

25 kHz

 

Frequency Stability

±5.0 ppm

 

Operating Temperature Range

-30 to +60°C

Battery Voltage

13.6 volts ± 10% (meets specs)

 

 

± 20% (operational)

Radio Current Drain

OFF:

0.01 amps

 

Rx Squelched: 0.9 amps

 

RxOn:

1.5 amps

 

Tx On:

10.0 amps

Size

170mm W x 216mm L x 53mm H

TRANSMITTER

 

 

Tx Two Frequency Spread

26 MHz

 

RF Power Output

40 watts (+ 146 dBm, Adjustable 20 to 40 watts)

Maximum Deviation

±5% kHz peak

Tx Duty Cycle

20% Intermittent (EIA)

FM Hum and Noise (EIA)

-45 dBc maximum

Audio Distortion

5% @ 300 Hz, 3% @ 1kHz, 5% @ 3kHz

RF Load Impedance

50 ohms

 

Audio Sensitivity

80 mV ±3 dB

Audio Frequency Response

Within + 1 ,-3 dB of a 6db/octave pre-emphasis,

 

300-3000 Hz (EIA)

Spurious Emissions

 

 

Conducted

-16.5 dBm max (Meets DOC & FCC)

Radiated

-13 dBm max (FCC)

RECEIVER

 

 

Receiver coverage

148-174 MHz

Factory Tuned

150-168 MHz

Rx Two Freq Spread

18 MHz (No degradation)

Channel Spacing

25/30 kHz

Sensitivity (12 dB SINAD)

-117 dBm (.30 μV)