Set Up for Esoteric Units

2

 

3

 

4

 

5

This is the recommended set up for synchronization with TEAC-ESOTERIC CD units:

P-70, X-01, UX-1, P-01, D-01

1Connect WORD CLOCK OUT terminals to WORD SYNC IN terminals of each unit using commercially available BNC coaxial cables.

P-70: turn ON the WORD SYNC IN switch (front panel), then set the PLL filter switch (back panel) to ‘MODE2’.

X-01: select ‘Word M1 ON’ using the CLOCK MODE button.

UX-1: select ‘Word ON’ using the CLOCK MODE button.

P-01: select ‘Rb IN’ using the WORD button.

D-01: select ‘Rb IN’ using the WORD button.

2Press the STANDBY/ON button to turn the unit on.

The standby indicator will turn off.

3Press the MASTER button to select which oscillator you will use for the reference frequency.

4Select 44.1kHz using the FREQUENCY MODE button.

5Select the frequency of the word clock for each line by pressing the A, B or C button.

<Set the frequency as high as the connected units will allow for synchronization.

P-70: 88.2 kHz

X-01: 176.4 kHz

P-01: 176.4 kHz

D-01: 176.4 kHz

NOTE:

If you connect this unit to other manufacturers units, be sure to read the manuals of those devices to confirm the frequency range of synchronization.

Dual AES connection will require you to set the clock frequency at one half of the audio signal frequency.

<“Rb” is recommended.