29" (73.7 cm) Electric Dryer
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
RECESSEDAREA AND CLOSET INSTALLATION
EXHAUST VENTING
EED4400W
BecauseWhirlpool Corporation policy includes a continuous commitment to improve
ourproducts, we reserve the right to change materials and specifications without notice.
Dimensionsare for planning purposes only. For complete details, see Installation
Instructionspacked with product. Specifications subject to change without notice.
Ref.W10150612B
07/2009
223/4"
(578mm)
433/8"
(1102mm)
*273/4"
(705mm) 29"
(737mm)
29"
(737mm)
*26"
(660mm)
433/8"
(1102mm)
151/4"
(387mm)
433/8"
(1102mm)
*273/4"
(705mm)
29"
(737mm)
223/4"
(578mm) 433/8"
(1102mm)
*273/4"
(705mm)
29"
(737mm)
133/4"
(349mm)
AB
CD
A.Recessed area
B.Side view - closet or conf ined area
C.Closet door with vents

ABC

18"*
(457mm)
1"
(25mm)
29"
(737mm)
1"
(25mm)
1"*
(25 mm)
14"max.*
(356mm)
27¾"
(705mm)
5"*
(127mm)
48in.
(310cm )
2
*
2
24in.
(150cm )
2
*
2
3"*
(76mm)
3"*
(76mm)
Forcloset installation
witha door, minimum
ventilationopenings in
thetop and bottom of
thedoor are required.
Louvereddoors with
equivalentair openings
areacceptable.
1.Select the route that will provide the straightest and most direct path outdoors. Plan the
installationto use the fewest number of elbows and turns. When using elbows or making turns,
allowas much room as possible. Bend vent gradually to avoid kinking. Use the fewest 90° turns
possible.
2.Determine vent length.
Themaximum length of the exhaust system depends upon:
•The type of vent (rigid metal or flexible metal).
•The number of elbows used.
•Type of hood.
Seethe exhaust vent length chart that matches your hood type for the maximum vent lengths you
canuse.
3.Determine the number of elbows you will need.
IMPORTANT:Do not use vent runs longer than specified in the Vent Length Chart.
Number of
90 turns
or elbows
Typeof
vent
Boxor
Louvered
hoods
Angled
hoods
0Rigidmetal 64ft (20 m) 58ft (17.7 m)
154ft (16.5m) 48ft (14.6 m)
244ft (13.4 m) 38ft(11.6 m)
335ft (10.7 m) 29 ft(8.8m)
427ft (8.2 m) 21 ft (6.4 m)
Rigidmetal
Rigidmetal
Rigidmetal
Rigidmetal
o
Electrical:To supply the required three- or four-
wire,single-phase, 120/240-volt, 60-Hz, AC-only
electricalsupply (or three- or four-wire,
120/208-voltelectrical supply, if specified on the
serial/ratingplate) on a separate 30-amp circuit,
fusedon both sides of the line. A time-delay fuse
orcircuit breaker is recommended. Connect to an
individualbranch circuit. Do not have a fuse in the
neutralor grounding circuit.
Exhaustventing: Exhaust your dryer tothe
outside.4" (102 mm) diameter heavymetal exhaust
ventand clamps must be used. DURASAFE™
ventingproducts are recommended.For best drying
performance,rigid metal vents are recommended.
Flexiblemetal vents are acceptableonly if accessible
forcleaning. Do NOT use plastic or metalfoil vent.
Exhaustoutlet hood must be at least 12"(304 mm)
fromthe ground or any object that may bein the
pathof the exhaust.
A.Small Opening
Side-SwingDoor
B.Large Opening
Side-SwingDoor
C.Wide Opening
Side-SwingDoor
D.Wide Opening
HamperDoor
*Mostinstallations require a minimum 5" (127 mm) clearance behind the dr yer for exhaust
ventwith elbow.
Louveredstyle
4"
(102mm)
4"
(102mm)
Boxhoodstyle
4"
(102mm)
Angledstyle
21/2"
(64mm)
VentSystem Chart
NOTE:Side and bottom exhaust installations have
a90° turn inside the dr yer.To determine maximum
exhaustlength, add one 90° turn to the chart.