Undercounter Dishwasher
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
TUD1000R TUD6710S
TUD4700M TUD6750R
TUD4700S TUD6750S
TUD6700P TUD6900P
TUD6710P
Electrical:
20 amp. electrical supply. Use copper wire only. A
Water: A hot water line with
24" (61 cm)*
(86 cm) min.
*to front of door frame
external pipe threads on one end to connect to water inlet valve. Do not solder within 6" (15.2 cm) from water inlet valve.
Drain: Use the new drain hose supplied with your dishwasher. If this is not suitable, use a new drain hose with a maximum length of 12 feet (3.7 m) that meets all current AHAM/IAPMO test standards, is resistant to heat and detergent, and fits the drain connector of the dishwasher. Must have a high drain loop 20 inches (50.8 cm) above the subfloor or floor. Connect drain hose to waste tee or disposer inlet above drain trap in house plumbing and 20 inches (50.8 cm) minimum above the floor. An air gap must be used if the drain hose is connected to house plumbing lower than 20 inches (50.8 cm) above subfloor or floor. Use 1/2" minimum I.D. drain line fittings.
Corner location: Requires a 2" (5.1 cm) minimum clearance between the side of the dishwasher door and wall or cabinet.
A side panel kit is available from your dealer for installing your dishwasher at end of cabinet.
Do not install dishwasher over carpeted floor.
CABINET OPENING DIMENSIONS |
|
|
|
| |
| 24" (61 cm)** |
|
|
| |
*Measured from the lowest point on the |
|
|
|
| |
underside of countertop. May be reduced |
|
|
| ||
to |
|
|
|
| |
from dishwasher. |
|
|
|
| |
**Minimum, measured from narrowest point |
|
|
| ||
of opening. |
| 24" (61 cm) | 34" (86.4 cm) min.* | ||
|
|
| |||
| 6"(15.2 cm) |
| 6"(15.2 cm) |
|
|
| 4" (10.2 cm) |
|
|
| |
4" |
|
|
| 4" |
|
|
|
| (10.2 cm) |
| |
(10.2 cm) |
|
|
|
| |
|
|
|
|
| |
10" |
|
|
| ||
(25.4 cm) |
|
| |||
(6.4 cm) |
| (6.4 cm) |
| ||
|
|
|
| ||
2" | 5" (12.7 cm) |
| 5" (12.7 cm) | 2" |
|
| (5.1 cm) |
| |||
(5.1 cm) |
|
|
|
| |
|
|
|
|
| |
Water line entering through the | Drain hose and power supply line entering through the right | ||||
left side of opening in shaded | side of opening in shaded areas makes connection easier. | ||||
areas makes connection easier. | Drain hose size: |
| |||
Minimum 1/2" (12,7 mm) hole. | Power supply line | ||||
|
| Power supply line |
CUSTOM FRONT PANEL DIMENSIONS (Framed)
These panels fit only models with frames around the door and access panels.
Cut door panel to clear access panel when door is in open position .
7/32" (5.6 mm)
door panel (side view)
7/32" (5.6 mm)
door panel (front view)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3/8" |
|
|
|
| |
| (9.5 mm) |
|
|
| ||
| 1" |
|
| 18 |
| 21/32" |
|
|
| (47.4 | cm) | ||
| (25.4 mm) |
|
|
| ||
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
22 31/32"
(58.3 cm)
NOTE: Access panel is wider than door panel.
23 5/16" (59.2 cm)
access panel (front view)
All edges routed to 7/32" (5.6 mm) thickness.
door closed
side view
door pivot
door opened
access panel
7/32" (5.6 mm) thick |
| |||||
|
|
|
|
| ||
top view |
| |||||
|
|
|
|
|
| 1/4" |
|
|
|
|
|
| |
|
|
|
|
|
| |
access panel frame |
|
| ||||
|
|
|
(6.4 mm) min.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. 8535436 |
Instructions packed with product. Specifications subject to change without notice. |