PD11P, PD11VP, PD11LP, PD11LVP Features:

Light Switch (PD11LP/LVP/LVSP) activates rack illumination; choice of HI or LOW intensity

Light Tubes (PD11LP/LVP/LVSP) illuminates up to 25 rack spaces

4 dual 20 amp U-grounded switched outlets per unit

1 dual 15 amp U-grounded "always on" and protected outlet

Digital Voltmeter Readout (PD11VP/LVP/LVSP) displays incoming line voltage

Resettable 20 amp thermal circuit breaker; 15 amp for front panel outlet

Lighted Outlet Power Switch activates protection and filtration to all switch outlets and front panel outlet

12-gauge, 3-prong, 10-foot, 20-amp power cord. Requires 20 amp circuit and receptacle outlet

Protected "always on" 15 amp AC power outlet on the front panel

Total unit 20 amp and 15 amp outlet circuit breakers located on front panel

Three-stage spike and surge protection

Two-stage EMI/RFI filtration

Ground and AC line fault check

One rack space high

One year limited warranty

PD11LVSP Features:

Microprocessor monitored sequential power distribution system

Four power up/down steps or stages of distributed and conditioned power

Four pre-set power up/down intervals of 1, 5, 10 or 30 seconds

Optional manual settings for up to 240 seconds between intervals

One dual 120 amp U-grounded outlet per stage

One dual 20 amp "always on" U-grounded outlet

Full 20 amps, 2400 watts capacity per unit

12-gauge, 3-prong, 10-foot, 20-amp power cord. Requires 20 amp circuit and receptacle outlet

Protected "always on" 15 amp AC power outlet on the front panel

Total unit 20 amp and 15 amp outlet circuit breakers located on front panel

Three-stage spike and surge protection

Two-stage EMI/RFI filtration

Ground and AC line fault check

One rack space high

One year limited warranty

Other Features:

Remote control operation

The remote feature is accessed externally through a 3-wire remote block

PD11LVSP/LVP/LP/VP/P Specifications:

Dimensions

19" L x 10" D x 1 3/4" H

Weight

10 lbs.

Quality Finish

Black powder coat chassis, black anodized aluminum front panel

Electrical

120V, 50/60 Hz, single phase

Max. amps

20/unit

Max. watts

2400/unit

Max. front outlet

15 amps

Spike/surge protection

Line to neutral, neutral to ground, line to ground

Clamping level

200V peak

Response time

1 nanosecond

Max. surge voltage

6000V

Max. surge current

23,000 amps (PD11LVSP/LVP/VP/LP/P)

Max. spike energy

630 joules total

Noise attenuation

Transverse > 20 dB, 1.5 kHz to 200 MHz

Certification

ETL listed