Euro-Pro EP664 Operating Instructions, Precautionary Measures, Trouble Shooting Guide, Problem

Models: EP664

1 6
Download 6 pages 40 Kb
Page 5
Image 5
OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

PRECAUTIONARY MEASURES

Motor Thermostat IMPORTANT: This unit is equipped with a motor protective thermostat. If for some reason the vacuum cleaner should overheat, the thermostat will automatically turn the unit off. Should this occur:

Push the On/Off button once.

Disconnect the plug from the power source.

Check the source of overheating problem. (i.e. clogged hose or filter)

If clogged hose or filter is found, unclog the hose and replace the filters.

Wait at least 45 minutes before attempting to reuse the vacuum.

After unit has cooled down for

45 minutes, plug in the cleaner and push the On/Off button. The vacuum should start again.

If the vacuum still does not start, contact customer service at

1 (800) 798-7398.

IMPORTANT: If the suction opening in the unit or the nozzle is BLOCKED, switch off the vacuum cleaner and remove the blocking substance before you start the unit again.

1. Do not operate the vacuum cleaner

4. When pulling out the power plug

too close to heaters, radiators or

from the wall outlet, pull the plug not

cigarette butts.

the power cord.

TROUBLE SHOOTING GUIDE

PROBLEM

 

POSSIBLE REASON

 

POSSIBLE SOLUTION

 

 

 

 

 

 

 

 

1.

Plug unit in firmly.

 

1.

Power cord not firmly plugged into

2.

Check fuse or breaker. Replace

VACUUM WILL

 

outlet.

 

fuse/reset breaker.

2.

No power in wall outlet.

3.

Call 1 (800) 798-7398.

NOT OPERATE

3.

Needs servicing.

4.

Turn the unit off and unplug from

 

 

4.

Thermostat has tripped.

 

outlet. Allow unit to cool down,

 

 

 

 

then restart.

 

 

 

 

 

 

 

 

1.

Empty and clean dust cup.

VACUUM WILL

 

 

2.

Turn unit off and unplug from

1.

Dust cup is full.

 

wall outlet. Remove dust cup

NOT PICK-UP OR

 

2.

Unit clogged.

 

filter and check for object(s) in

SUCTION POWER

 

3.

Filter needs cleaning or replacing.

 

the air intake opening and

IS WEAK

 

 

 

 

remove.

 

 

 

 

 

 

 

3.

Clean or replace filter.

 

 

 

 

 

DUST ESCAPING

1.

Dust cup is full.

1.

Empty and clean dust cup.

2.

Dust cup is not installed correctly.

2.

Review dust cup instructions.

FROM VACUUM

3.

Filter is not in unit.

3.

Install filter in unit.

 

 

 

 

 

 

BRUSH OR FLOOR

1.

Brush or floor nozzle is clogged.

1.

Remove brush and/or floor

 

nozzle. Remove obstruction

NOZZLE WILL NOT

2.

Dust cup is full.

 

from brush and /or floor nozzle.

PICK-UP

3.

Filter need cleaning or replacing.

2.

Empty and clean dust cup.

 

 

 

3.

Clean or replace filter.

2.Before inserting the power plug into the wall outlet, make sure that your hands are dry.

3.Before you start vacuuming, make sure to remove large or sharp objects that might damage the dust cup.

5.Do not pick up anything that is burning or smoking such as cigarettes, matches or hot ashes.

6.Do not use without filter in place.

6

3

Page 5
Image 5
Euro-Pro EP664 Operating Instructions, Precautionary Measures, Trouble Shooting Guide, Problem, Possible Reason