TROUBLSHOOTING

Do not operate the steam generator with a damaged cord, plug or if the iron or any other part of the system has been dropped or damaged. To avoid the risk of electric shock, do not disassemble or attempt to repair the ironing system. Return the appliance to EURO-PRO Operating LLC (see Warranty) for examination and repair.

ADDITIONAL IMPORTANT SAFEGUARDS

Read all instructions before using the EURO-PRO Operating LLC Steam Generator Iron and follow all the instructions and safeguards carefully.

Incorrect re-assembly or repair can cause a risk of electric shock or injury to persons when the ironing system is used.

PROBLEM

 

POSSIBLE CAUSES

 

SOLUTIONS

 

 

 

 

 

 

 

1. Press the On/Off button to

 

1. On/Off button is not in the

 

the “ON” position.

 

2. Fill with water as per

 

 

“ON” position.

 

 

 

instructions.

 

2. Steam generator has no more

 

No Steam Is

3. Make sure that the On/Off

 

water.

 

 

button is in the “OFF”

Released

3.

Unit is not plugged in.

 

position and plug the unit

Through The

4.

Steam is not visible because

 

into an electrical outlet.

Iron

 

the temperature of the

4/5. The heating time for the

 

 

soleplate is at maximum and

 

generator is approximately

 

 

room temperature is high.

 

11-13 minutes. Watch for

 

5.

Generator is not fully heated.

 

the steam ready light to go

 

 

 

 

off indicating that steam is

 

 

 

 

ready.

The Soleplate

1. Temperature is set at

1.

Turn the temperature

 

control dial to the desired

Remains Cold

 

“Minimum”.

 

 

 

setting.

 

 

 

 

 

 

 

 

 

Drops Of Water

1.

Soleplate temperature is too

1.

Turn the temperature

 

control dial to the marks

Leak From The

 

low to iron with steam.

 

between 2 and 3 dots.

Iron Soleplate

2.

Generator is not fully heated.

2.

Wait for generator to be

 

 

 

 

fully heated.

Dirty Or Yellow

1. Residue is water tank.

1.

Clean steam generator as

Steam Is

 

per instructions.

2.

Not using demineralized/

2.

Use demineralized/ distilled

Coming Out Of

 

distilled water.

 

water after cleaning the

The Iron

 

 

 

tank.

Steam Leaking

1. Gasket is broken because

1.

Order new boiler filler cap

 

boiler filler cap was closed too

From The Boiler

 

tightly or cap was opened

 

from customer service at 1

Filler Cap

 

while tank was full of steam

 

(800) 798-7398.

 

 

and gasket broke.

 

 

CAUTION! NEVER open the boiler filling cap before ALL the remaining steam has been released from the steam generator and the steam generator has cooled. To release the steam, press the On/Off button to the “Off” position and push the steam button on the iron until no more steam comes out of the iron. Then open the boiler filler cap slowly.

A WORD ON WATER

For best results we recommend using 100% demineralized/distilled water.

You can use regular tap water in your steam generator, but should the water in your area be hard water we strongly recommend the use of 100% demineralized/distilled water. This will prolong the life of your generator and reduce the frequency of required generator cleaning, as well as the possibility of staining due to accumulated impurities.

DO NOT USE WATER PROCESSED THROUGH A HOME WATER SOFTENING SYSTEM OR BOTTLED MINERAL WATER.

DO NOT OVERFILL THE STEAM GENERATOR

When empty, the steam generator can be filled with 26 U.S. fl. oz. of demineralized/ distilled water. Do NOT overfill. Overfilling the water tank can cause water drops to come out of the steam holes. See filling instructions on page 5.

DO NOT OVER TIGHTEN THE BOILER FILLER CAP

To close the boiler filler cap, turn clockwise until the point where you feel friction – do NOT close too tightly. The boiler filler cap has a gasket which can be flattened and damaged if the cap is closed too tightly. If the gasket is damaged, steam may escape while the steam generator is being used. If the boiler filler cap is damaged and steam is leaking, call customer service to purchase a replacement boiler filler cap.

NEVER LEAVE THE HOT IRON RESTING ON THE IRON REST FOR LONG PERIODS OF TIME

The lifespan of your steam generator will be reduced if the iron is left idle at high temperatures for extended periods of time. If the iron is not in use, reduce the temperature to the lowest temperature setting on the temperature control thermostat, turn the steam generator “Off” and remove the power cord from the electrical power outlet.

WARRANTED FOR REGULAR HOUSEHOLD USE

This Steam Generator Ironing system is intended for and warranted only for normal household use. The iron and/or steam generator should not be used for more than fifteen (15) hours per week in approximately three (3) hour intervals.