TROUBLSHOOTING
Do not operate the steam generator with a damaged cord, plug or if the iron or any other part of the system has been dropped or damaged. To avoid the risk of electric shock, do not disassemble or attempt to repair the ironing system. Return the appliance to
ADDITIONAL IMPORTANT SAFEGUARDS
Read all instructions before using the
Incorrect
PROBLEM |
| POSSIBLE CAUSES |
| SOLUTIONS | |
|
|
|
| ||
|
|
| 1. Press the On/Off button to | ||
| 1. On/Off button is not in the |
| the “ON” position. | ||
| 2. Fill with water as per | ||||
|
| “ON” position. | |||
|
|
| instructions. | ||
| 2. Steam generator has no more |
| |||
No Steam Is | 3. Make sure that the On/Off | ||||
| water. | ||||
|
| button is in the “OFF” | |||
Released | 3. | Unit is not plugged in. |
| position and plug the unit | |
Through The | 4. | Steam is not visible because |
| into an electrical outlet. | |
Iron |
| the temperature of the | 4/5. The heating time for the | ||
|
| soleplate is at maximum and |
| generator is approximately | |
|
| room temperature is high. |
| ||
| 5. | Generator is not fully heated. |
| the steam ready light to go | |
|
|
|
| off indicating that steam is | |
|
|
|
| ready. | |
The Soleplate | 1. Temperature is set at | 1. | Turn the temperature | ||
| control dial to the desired | ||||
Remains Cold |
| “Minimum”. |
| ||
|
| setting. | |||
|
|
|
| ||
|
|
|
|
| |
Drops Of Water | 1. | Soleplate temperature is too | 1. | Turn the temperature | |
| control dial to the marks | ||||
Leak From The |
| low to iron with steam. |
| between 2 and 3 dots. | |
Iron Soleplate | 2. | Generator is not fully heated. | 2. | Wait for generator to be | |
|
|
|
| fully heated. | |
Dirty Or Yellow | 1. Residue is water tank. | 1. | Clean steam generator as | ||
Steam Is |
| per instructions. | |||
2. | Not using demineralized/ | 2. | Use demineralized/ distilled | ||
Coming Out Of | |||||
| distilled water. |
| water after cleaning the | ||
The Iron |
|
|
| tank. | |
Steam Leaking | 1. Gasket is broken because | 1. | Order new boiler filler cap | ||
| boiler filler cap was closed too | ||||
From The Boiler |
| tightly or cap was opened |
| from customer service at 1 | |
Filler Cap |
| while tank was full of steam |
| (800) | |
|
| and gasket broke. |
|
|
CAUTION! NEVER open the boiler filling cap before ALL the remaining steam has been released from the steam generator and the steam generator has cooled. To release the steam, press the On/Off button to the “Off” position and push the steam button on the iron until no more steam comes out of the iron. Then open the boiler filler cap slowly.
A WORD ON WATER
For best results we recommend using 100% demineralized/distilled water.
You can use regular tap water in your steam generator, but should the water in your area be hard water we strongly recommend the use of 100% demineralized/distilled water. This will prolong the life of your generator and reduce the frequency of required generator cleaning, as well as the possibility of staining due to accumulated impurities.
DO NOT USE WATER PROCESSED THROUGH A HOME WATER SOFTENING SYSTEM OR BOTTLED MINERAL WATER.
DO NOT OVERFILL THE STEAM GENERATOR
When empty, the steam generator can be filled with 26 U.S. fl. oz. of demineralized/ distilled water. Do NOT overfill. Overfilling the water tank can cause water drops to come out of the steam holes. See filling instructions on page 5.
DO NOT OVER TIGHTEN THE BOILER FILLER CAP
To close the boiler filler cap, turn clockwise until the point where you feel friction – do NOT close too tightly. The boiler filler cap has a gasket which can be flattened and damaged if the cap is closed too tightly. If the gasket is damaged, steam may escape while the steam generator is being used. If the boiler filler cap is damaged and steam is leaking, call customer service to purchase a replacement boiler filler cap.
NEVER LEAVE THE HOT IRON RESTING ON THE IRON REST FOR LONG PERIODS OF TIME
The lifespan of your steam generator will be reduced if the iron is left idle at high temperatures for extended periods of time. If the iron is not in use, reduce the temperature to the lowest temperature setting on the temperature control thermostat, turn the steam generator “Off” and remove the power cord from the electrical power outlet.
WARRANTED FOR REGULAR HOUSEHOLD USE
This Steam Generator Ironing system is intended for and warranted only for normal household use. The iron and/or steam generator should not be used for more than fifteen (15) hours per week in approximately three (3) hour intervals.