2-13
2.3.1. Address Setting
The address code of the EPTZ1000should be set to correspond properly with a control
device to control multiple dome cameras. The address codes are made up by the
dipswitch SW1 (8 bits) on the PCB board. The 8 bits dipswitch indicates the binary
coded of the address, and there are 256 addresses can be selected (0 ~ 255, 28 = 256).
It also means that there up to 256 dome cameras can cascade on the RS485 bus. The
dipswitch setting and the indicated address are represented in the following chart.
Note: The factory default address is 1.
Notice: Please make sure the power is off before setting, and restart the speed dome
to enable a new value after changing.
SW1
ON
12345678
CPU
ON
12345678
SW2
ID1
ID2
ID3
ID4
ID5
ID6
ID7
ID8
Protocol
BAUD