Installation and Operation Guide

KleenSteam® Systems • Models BB & CT

READ THESE IMPORTANT POINTS BEFORE INSTALLING THIS KLEENSTEAM® SYSTEM:

1.Always use a minimum 3/8” O.D. copper tubing from the outlet of the KleenSteam unit to your steamer.

2.Use the water from the KleenSteam unit only on steamer feed and make-up water.

DO NOT USE TO TREAT CONDENSATE COOLING WATER.

3.For many years, Everpure has worked closely with all major foodservice equipment manufacturers to assure the highest possible degree of compatibility and optimal performance of the KleenSteam System with their steamers.

To help ensure satisfactory operation, we recommend that you obtain and read the equipment manufacturer’s operating and maintenance instructions for your specific steamer model. Follow the manufacturer’s instructions and procedures for installation, maintenance and cleaning. Or consult with the manufacturer’s representative or technical service personnel for guidance regarding any differences between their directions and those included with the KleenSteam System. Failure to do so may affect equipment performance and/or warranty coverage.

INSTALLATION INSTRUCTIONS

Do not make any disconnections until you have inspected the contents of the KleenSteam unit carton. You should have:

KleenSteam plate-mounted system consisting of:

-Quick-change filter head with 7CB5 Filter Cartridge (BB System) or 4CB5 Filter Cartridge (CT System)

-AR-X Housing

-ScaleStick SS-10

-Dip Tube for ScaleKleen delimer

(4) ScaleKleen 2.2 lb. packets (BB System)

(2) ScaleKleen 7 oz packets (CT System)

If you do not have these components, do not attempt to install this system!

Contact your local Everpure Master Distributor for assistance.

1.Shut off power to the steamer.

2.Shut off the inlet water to the steamer at the supply valve.

3.Attach the plate-mounted KleenSteam system to a suitable structure in an accessible location. Mounting holes are provided on the mounting plate. THE KLEENSTEAM BB WEIGHS 25 POUNDS IN SERVICE. THE KLEENSTEAM CT WEIGHS 15 POUNDS IN SERVICE.

4.Attach the inlet of the KleenSteam unit to a COLD water supply line only. Hot water will damage the KleenSteam unit and will void the warranty. Use a minimum of 3/8” tubing.

5.Attach only copper or stainless steel tubing from the outlet of the KleenSteam system to the inlet feed/makeup water connection on your steamer. Keep the tubing run to the steamer under 20 feet. DO NOT CONNECT TO CONDENSATE COOLING LINE.

6.Install 7CB5 or 4CB5 Filter Cartridge into the quick-change filter head as instructed on the cartridge label.

7.Unscrew the clear bowl and insert the SS-10 ScaleStick into the center port of the AR-X head. The friction fit between the cartridge and port should allow the cartridge to be suspended while placing the clear bowl over the cartridge and threading it into place on the head. NOTE: The cartridge must be replaced when the level of the white material drops below 1/4” in depth. Take care not to block the KleenSteam unit from view when installing.

8.With the supply water to the KleenSteam unit off, rotate the inlet valve handle to the open position.

9.Attach tubing to the outlet of the flushing valve and open the valve.

10.Turn on the inlet supply water and flush the 7CB5 or 4CB5 cartridge to drain (or bucket) at full force for several minutes. This will flush incidental carbon fines and any trapped air.

11.After flushing, close the flushing valve handle until the water stops.

12.Depress red pressure relief button on the AR-X head until water flows out and around the red button.

13.Inspect KleenSteam unit for leaks, and correct as required.

14.Turn on power to steamer.

DELIMING INSTRUCTIONS

In addition to reducing harmful chlorine and controlling limescale build-up, the KleenSteam system may be used to conveniently introduce deliming material into the steamer without disturbing existing piping.

Use only Everpure ScaleKleen deliming material. ScaleKleen is a highly effective, safe and environmentally friendly de-scaling product. Its routine maintenance usage removes built-up scale in steam equipment easily and quickly. This enhances steamer performance, reduces operating costs and helps prevent costly repairs and unexpected downtime. Other deliming products may contain harsh acids that can damage the housing materials or clog orifices. Generally, use one

2.2lb (1 kg) package to delime most countertop units and four 2.2 lb packages to delime most boiler-based units.

1.Turn off the power switch on the steamer.

2.Blow down steamer. Blow down is done automatically on some steamers when power is turned off. Manually blow down the steamer if it is not automatic.

3.Turn off inlet water to Kleensteam system.

4.Depress the red relief button located on top of the AR-X head to relieve system pressure.

5.Unscrew the clear bowl and remove the cartridge. Dispose of the exhausted cartridge in normal trash and empty bowl of any remaining water.

6.Remove the dip tube from it’s holding clip, located on the backplate. Insert the tube. O-ring first, into the center port of the AR-X head until the dip tube bottoms out.

7.Open one kilogram (2.2 lb) package of ScaleKleenand empty it

EV3111-58B FE05

Page 1
Image 1
Everpure CT, BB warranty Installation Instructions, Deliming Instructions