C E S 2 7 5 0 S e r i e s

W a t e r C o n d i t i o n e r

Water Conditioning for Commercial and Light Industrial Applications

Available in Single Tank System with 1” Porting

 

 

 

B E N E F I T S

 

 

 

 

 

 

 

Hardness removal of 34,000 to 101,000 grains at

 

 

 

flow rates up to 20 gallons per minute continuous

 

 

 

Meter initiated regeneration minimizes salt,

 

 

 

water, and electrical costs

 

 

 

Advanced user-friendly controls incorporates

 

 

 

time-tested hydraulically balanced piston,

 

 

 

seal and spacer design to pilot service flow

 

 

 

and regeneration

 

 

 

Large capacity brine tank maximizes time

 

 

 

between refills

 

 

 

Fiberglass reinforced resin vessels with NSF

 

 

 

approved polyethylene liners eliminate worries

 

 

 

about corrosion

 

 

 

Single tank design for simplicity, economy

 

CES-2750M34:

EV9982-21

and space savings

 

MRS-20T System: EV9797-92

 

 

CES-2750M-51:

EV9982-22

Fully adjustable 5-cycle control delivers

 

CES-2750M-68:

EV9982-23

 

controlled upflow backwash, downflow brining

 

4MR-1 Cartridge: EV9273-69

 

CES-2750M-101:

EV9982-24

and slow rinse, rapid rinse, timed brine refill and

 

 

 

 

 

 

downflow service

 

 

 

I N S T A L L A T I ON T I P S

OP E R A T I ON T I P S

A P P L I CA T I ON / S I Z I N G

 

 

 

Locate equipment on a smooth, level surface

Check for softened water each time salt is

Warewashing

Maintain an air-gap at the end of the drain line

added, by using a soap or hardness test kit

Laundry - Linen & Uniform

Use a good quality grade of salt -Solar

 

 

Secure drain line directly over floor drain or

or pellet are preferred

 

Boiler Scale Control

stand pipe

Check the salt level on a regular basis

Water Heater Scale Protection/Reduction

When connecting to a water heater, install a

Maintain at minimum salt depth of 6” to

General Housekeeping

check valve on the soft water piping to prevent

hot water back-up

ensure a proper regeneration

 

When sweating/installing copper piping,

On iron bearing waters, use a salt that

 

protect the control valve from excessive heat

contains an iron “fighting” additive, or use

 

Check local codes for additional equipment

a resin cleaner on a regular basis

 

Check the water level in the brine tank

 

that may be required, such as backflow

 

prevention devices (i.e., RPZ)

If abnormally high - refer to IO guide for

 

 

troubleshooting information

 

 

 

 

 

Page 1
Image 1