Installation and Operation Guide
QL2-OW200L Water Filter & Cartridge
Not for use with water preheated over 100 °F (38 °C)
The Everpure
Perhaps most important, the OW200L reduces both lead and trihalomethanes (THMs) to below Federal limits.
Parts List
Key Letter | Description | Part No. |
A | QL2 Head Assembly | |
B | OW200L Cartridge | |
C | Mounting Screw (2 req’d) | |
D | Star Washer (2 req’d) | |
E | Flow Control/Quick Disconnect | |
F | Mounting Bracket | |
G | Bracket Screw (3 req’d) |
Specifications
Rated Service Flow: | 0.5 gpm / 1.9 Lpm |
Maximum Working Temperature: | |
Min/Max Operating Pressure: | 10 psi (0.7 bar)/125 psi (8.6 bar) |
Capacity: | 480 gallons (1816L) |
Flow Rate: | 0.5 gpm (1.9 Lpm) |
For cold water use only. |
|
This drinking water system must be maintained in accordance with the manufacturer’s instructions, including the timely replacement of filter cartridges.
Installation
INCOMING FITTING FROM COLD WATER SUPPLY PROVIDED BY INSTALLER
F E
G | TO DISPENSER |
| WATER INLET |
D C
A
B
The following instructions provide for installation of a
1.Install the
2.Select a location for the filter (nominally 4” x 4” x 22” long including a
3.If required, shut off the incoming water supply and relieve pressure in the water line. Cut the tubing, allowing a 4” space for the filter installation between the water supply and the cooler water inlet.
4.Note the arrow in the top of the QL2 head assembly (refer to item “A” on reverse side of page). This indicates the water flow, from left to right. Note that a 3/8” flow control/quick disconnect fitting (E) has been installed in the outlet (right hand) port.
5.Install a fitting (not supplied) into the inlet (left hand) port. Do not overtighten the fitting. Use Teflon tape or food grade pipe joint sealant on fittings.
6.Cut the end of the outlet tubing with a sharp knife, making sure the tube end is cut flat. Insert the tube end onto the quick disconnect fitting
(E) and push firmly until the tube end bottoms out in the fitting. To remove the tubing, push the gray ring tight against the fitting while pulling the tubing out.
7.Position the QL2 head assembly so that the arrow shown on top of the head corresponds to the direction of water flow and attach the incoming cold water supply to the inlet of the head.
8.Connect the filter outlet to the water cooler inlet line, and secure in place by tightening the compression nuts.
9.Mount the head to the wall or the cabinet using the screws (C) and star washers (D) provided.
10.Install the OW200L cartridge (B) into the head following the instructions on the cartridge label.
11.Turn on the water and check for leaks.
12.Run water through the OW200L cartridge for three minutes at maximum flow to purge the cartridge of air.