ROMII/ROMIII | product specifications |
for the home | |
| Commercial grade reverse osmosis systems |
ROM II Reverse Osmosis Drinking Water System (
TFC RO Cartridge “B” (EV9273-70)
ROM III VOC #1 Cartridge “C”
Features:
>Finely polishes treated water to premium quality for drinking and cooking.
>Reduces chlorine taste and odor.
>Reduces dirt, rust, asbestos fibers, and other particulates such as oxidized iron, manganese, and sulfides.
>Reduces parasitic protozoan cysts such as Giardia, Entamoeba, and Cryptosporidium.
>Controls even extreme levels of common “off” tastes and odors, including those which are earthy, moldy, and fishy.
>Reduces lead to below the Federal Action Level.
>Effectively reduces Volatile Organic Chemicals (VOCs), including Trihalomethanes (THMs).
>Effectively reduces methyl
>Inhibits limescale
General Installation/Operation/Maintenance Requirements:
>It is recommended that before purchasing a water treatment unit, you have your water tested to determine your actual treatment needs.
>Space required: 12” wide x 17” high x 4” deep (30 x 43 x 10 cm), plus an additional 3 inches of clear space under unit for cartridge change.
>Install vertically with cartridges hanging down.
>Use minimum length of tubing possible.
>Flush all cartridges,“A”, “B” and “C” per Installation and Use Manual provided with unit.
>
>A separate drinking water faucet is required.
This system has been tested by Everpure for the reduction of the substances listed below.
| Influent Challenge | Max. Permissible Product | Reduction | Minimum | Average |
Substance | Concentration | Water Concentration | Requirements | Reduction | Reduction |
Arsenic | 0.30 mg/L ± 10% | 0.025 mg/L |
| 96.6% | 98.0% |
Barium | 10.0 mg/L ± 10% | 2.0 mg/L |
| 90.0% | 90.0% |
Cadmium | 0.03 mg/L ± 10% | 0.005 mg/L |
| 90.0% | 96.4% |
Chromium (Hexavalent) | 0.3 mg/L ± 10% | 0.1 mg/L |
| 86.6% | 86.6% |
Chromium (Trivalent) | 0.3 mg/L ± 10% | 0.1 mg/L |
| 85.7% | 85.7% |
Copper | 3.0 mg/L ± 10% | 1.3 mg/L |
| 96.5% | 99.2% |
Fluoride | 8.0 mg/L ± 10% | 1.5 mg/L |
| 89.9% | 95.2% |
Lead | 0.15 mg/L ± 10% | 0.010 mg/L |
| 97% | 98.1% |
Nitrate plus Nitrite (both as N) | 30.0 mg/L ± 10% | 10.0 mg/L |
|
|
|
Nitrate(as N) | 27.0 mg/L ± 10% | 10.0 mg/L |
| 74.3% | 80.4% |
Nitrite(as N) | 3.0 mg/L ± 10% | 1.0 mg/L |
| 68.3% | 75.8% |
Selenium | 0.10 mg/L ± 10% | 0.05 mg/L |
| 93.0% | 96.8% |
Radium 226/228 | 25 pCi/L ± 10% | 5 p/Ci/L |
| 80.0% | 80.0% |
Total Dissolved Solids | 750 mg/L ± 40 ug/L | 187 mg/L |
| 92.4% | 94.6% |
Cyst | Minimum 50,000/L |
| 99.95% | 99.99% | 99.99% |
MTBE* | 0.015 mg/L ± 20% | 0.005 mg/L |
| 77.8% | 92.1% |
Chloroform | 0.30 mg/L | 0.15 mg/L |
| 95.0% | 99.0% |
VOCs* | 265 ppb | 10 ppb |
| 96.0% | 99.0% |
Actual system performance may vary depending on water pressure, water temperature and other substances which may be found in water.
This drinking water system must be maintained according to the manufacturer's instructions, including replacement of filter cartridges. The substances reduced or removed by this system are not necessarily in your water. Read the performance data sheet.
flow rateControlled at 0.5 gal./min. (1.9 L/min.)minimum temperature* this may vary depending on specific water conditions
everpure warrantyEverpure Drinking Water Systems are warranted to be free of defects for a full twelve (12) months after purchase. A detailed warranty statement is provided with each system.
Everpure,®