Everpure product specifications, SPA-400 System - Part No. EV9270-90, flow rate, temperature

Models: SPA-400

1 2
Download 2 pages 59.38 Kb
Page 2
Image 2
SPA-400

SPA-400

product specifications

Commercial grade drinking water system for the home spa and bath

SPA-400 System – Part No. EV9270-90
SPA-400 Cartridge – Part No. EV9270-91
Features:

>Finely polishes treated water to premium quality for drinking.

>Reduces chlorine taste and odor.

>Reduces dirt, rust, and other particulates such as oxidized iron, manganese, and sulfides.

>Reduces parasitic protozoan cysts such as Giardia, Entamoeba, and Cryptosporidium.

>Reduces common earthy, moldy, fishy tastes, and odors.

>Reduces lead to below the Federal Action Level.

General Installation/Operation/Maintenance Requirements:

>It is recommended that before purchasing a water treatment unit, you have your water tested to determine your actual treatment needs.

>Space required: 5 x 5 x 20 in. (13 x 13 x 51 cm) including 2-1/2 inches of clear space under unit for cartridge change.

>Install vertically with cartridge hanging down.

>Use minimum length of tubing possible.

>Flush new cartridge at full flow for three minutes to purge air.

>Replace cartridges when capacity is reached, or when flow becomes too slow, but at least annually.

>Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

>System comes complete with filter cartridge, head, fittings, and connector.

HEALTH CLAIM PERFORMANCE CLASSIFIED BY UL

This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.

 

 

Max. Permissible

 

 

 

 

Influent Challenge

Product Water

Reduction

Minimum

Average

Substance

Concentration

Concentration

Requirements

Reduction

Reduction

 

 

 

 

 

Standard 42—Aesthetic Effects

 

 

 

 

 

 

 

 

 

 

Chlorine

2.0 mg/L ± 10%

 

≥ 50%

 

98%

Particulate,

 

 

 

 

 

Class I

at least 10,000

 

≥ 85%

 

99.8%

particles 0.5

particles/mL

 

 

 

 

 

 

to <1 µm

 

 

 

 

 

Standard 53—Health Effects

 

 

 

 

 

 

 

 

 

 

Cyst

Minimum 50,000/L

 

99.95%

99.99%

99.99%

Lead 8.5

0.15 mg/L ± 10%

0.010 mg/L

 

94.1%

97.2%

Lead 6.5

0.15 mg/L ± 10%

0.010 mg/L

 

98.9%

98.9%

Turbidity

11±1 NTU

0.5 NTU

 

98%

99%

†NTU = Nephelometric Turbidity Units

This drinking water system must be maintained according to the manufacturer's instructions, including replacement of filter cartridges. The substances reduced or removed by this system are not necessarily in your water. Read the performance data sheet.

flow rate
Controlled at 2.2 gal./min. (8.3 L/min.)
temperature
35-100 °F (2-38 °C) cold water use only
pressure
10-125 psi. (0.7-8.6 bar), non-shock
capacity
3,000 gal. (11,356 L)
everpure warranty

Everpure Drinking Water Systems are warranted to be free of defects for a full twelve (12) months after purchase. A detailed warranty statement is provided with each system.

ANSI/NSF

STANDARDS

42 and 53

System Tested and Classified by Underwriters Laboratories against NSF/ANSI Standards 42 and 53 as verified and substantiated by test data for the reduction of:

Std. No. 42—Aesthetic effects

Std. No. 53—Health effects

Chemical Reduction

Chemical Reduction

ChlorineLead
Taste & OdorMechanical Filtration

Mechanical Filtration

Cyst

Nominal Particulate Class I

Turbidity

Everpure,® Micro-Pure®and the silver canister color are registered trademarks of Everpure, LLC © 2008

Page 2
Image 2
Everpure SPA-400 product specifications, Commercial grade drinking water system for the home spa and bath, flow rate, Lead