Overview
The Extron CAT 6 Installation Kits include a pretested, plenum or
Termination of CAT 6 Cable
Figure 1 details how the CAT 6 cables in the Installation Kits are terminated in accordance with the TIA/EIA T 568A wiring standards.
Side | Clip Down |
|
|
|
|
| 1 2 3 4 5 6 7 8 |
|
|
| |
|
|
|
| ||
|
|
|
| RGB video and audio | |
|
| Pin | Wire color | Signal | Level |
|
| 1 | Red/V. sync+ | ±0.35V | |
|
| 2 | Green | Red/V. sync- | ±0.35V |
|
| 3 | Audio & | +15V with | |
|
| power | ±0.5 V | ||
|
| 4 | Blue | Green+ | +0.35V |
| 1 2 3 4 5 6 7 8 | 5 | Green- | ||
|
| ||||
|
| 6 | Orange | Audio & | ±0.5 V |
|
| power | |||
|
|
|
|
| |
|
| 7 | Blue/H. sync+ | ±0.35V | |
|
| 8 | Brown | Blue/H. sync- | ±0.35V |
Twisted Pairs
feet or less should exhibit no transmission problems if they pass CAT
Equalizing Pair Skew
The manufacturing process for CAT 6 cable leads to a condition called pair skew. Skew exists between pairs when the physical length of one wire pair is different from another. As the transmission cable length increases, the amount of skew increases. Skew affects the displayed image when the differential length between wire pairs exceeds 2 feet, causing the timing of the red, green, and blue video signals to appear out of alignment (horizontal registration errors). A white vertical line on a black field can appear as individual red, green, and blue lines that are close together; the signal transmitted on the shortest wire pair leads the other colors and appears to the left on the display.
CAT 6 cable test equipment measures and reports wire pair length. The report on the various pair lengths can be used in equalizing pair skew. The nominal velocity of propagation (NVP
—the speed at which the signal travels on the transmission line, measured as a percentage of the speed of light) of CAT 6 cable is very close to that of conventional coaxial cable. The similarity in NVP means that an additional length of coax equal to the length of pair skew, placed on the receiver’s output, equalizes the effects of pair skew (figure 2).
The installation kit includes skew compensation cable(s) that compensate(s) for the level of skew observed in testing at Extron.
TP T 15HD A
1&27&8
3&6 4&5
Figure 1 — CAT 6 cable termination
Cable Testing
To ensure proper cable termination, each transmission cable sold as part of an Installation Kit is tested from end to end to give an accurate indication of cable quality.
A complete test measures cable length and tests the wire map, attenuation, NEXT, PSNEXT, ELFEXT, PSELFEXT, return loss, ACR, and PSARC. All of these tests are critical for digital data transfer. While all of these tests are important indicators of the quality of the cable termination, the most critical testing parameters for video transfer are wire map
Audio
PC Computer
Pair | RGB video |
|
|
1, 2 | Red |
|
|
4, 5 | Green |
|
|
7, 8 | Blue |
CAT 6 Cable
... THEN insert a four foot extension cable to equalize TP skew for red video.
IF cable measurement indicates that the pair with wires 1 and 2 is four feet shorter than the other pairs...
TP R BNC A
LCD Projector
2CAT 6 Install Kit • Cable Testing
Figure 2 — Pair skew equalization
CAT 6 Install Kit • Equalizing Pair Skew | 3 |