Command ASCII Command
(Host to Device)
Response
(Device to Host)
Additional Description
Internal temperature
View internal temperature 20S X!] Internal temperature in
degrees Fahrenheit and
Celsius.
Factory reset
System reset (factory default) EZXXX}Zpx]Resets unit to factory
default (see System Reset
on page 12).
Reset audio gain and
attenuation
EZA}Zpa]Reset audio gain and
attenuation to default levels.
Upload firmware
Upload firmware EUpload}SendHeader]
SFP module
View SFP module information 40S X1*•X1(•X2)•X2! ]
NOTE: X! = Internal temperature
X1* = Vendor or manufacturer name
X1( = Transmit (Tx) output power in dBm
X2) = Receive (Rx) optical power in dBm
X2! = Operation temperature of the SFP modules in degrees Celsius
FOX T UWP 302 Wallplate Transmitter • SIS Configuration and Control 20