Installation, cont’d
Preparing the Table and Mounting the Enclosure
The preferred and recommended method for preparing the table is to use the appropriate Extron metal routing template and a router. The templates are available at no cost. See the part numbers for the templates in appendix A, “Reference Information”.
Alternatively, you can use a paper
Prepare the table as follows:
| CAUTION | The opening in the table for the HSA should be cut | |
|
|
| only by licensed and bonded craftspeople. Exercise |
|
|
| care to prevent scarring or damaging the furniture. |
|
|
| The routing templates for the various HSA models |
|
|
| are not interchangeable. If you use the wrong |
|
|
| template, you will cut an |
|
|
| you use a larger template than required, the cut will |
|
|
| result in gaps in the table surface on either side of |
|
|
| the enclosure. |
|
|
| The surfaces of the HSA enclosure have screws and |
|
|
| other protruding hardware that could damage fine |
|
|
| furniture. Do not rest the enclosure on unprotected |
|
|
| furniture. |
|
| The metal routing template is reusable. Do not discard | |
|
| ||
|
| the template when the installation is complete. Save it | |
|
| for installing other HSA products of the same size. | |
1. | Locate the desired mounting location on the tabletop or | ||
| other installation surface. Mark the location. | ||
|
| Ensure that only the wooden strips on the routing | |
| CAUTION | ||
|
|
| template contact the furniture. Failure to do so may |
|
|
| mar the furniture. |
2. | Place the mounting template assembly on the table, | ||
| centered on the mounting location. Angle the template for | ||
| the optimum positioning. If necessary, use a square to | ||
| ensure that the template is properly positioned. Extron is | ||
| not responsible for | ||
3. | Once the template assembly is positioned properly, secure | ||
| the assembly to the table with |
Figure 2-2 — Cutting the opening with a router
|
|
|
|
| Wear safety glasses when operating the router. |
|
|
|
|
| Failure to comply can result in eye injury. |
4. | Using a router with a 5/8" (or 16 mm) outside diameter | ||||
| guide bushing and a 1/2" (or 12 mm or 12.7 mm) diameter | ||||
| straight router bit, carefully cut the opening in the table | ||||
| surface (figure | ||||
5. | Remove the | ||||
|
|
|
|
| The flanged edges of the top of the surface enclosure |
|
|
|
| ||
|
|
|
|
| are sharp. To prevent personal injury, exercise |
|
|
|
|
| caution when the HSA is not installed in a table. |
|
|
| The flanged edges of the top of the surface enclosure | ||
| CAUTION |
| |||
|
|
|
|
| are bevelled to an |
0.04(4/100)" (approximately 1 mm). These edges are soft and can be easily nicked or bent. Exercise caution when handling and mounting the enclosure. Mishandling can damage the appearance of the enclosure.
6. Remove the plastic strips that protect the flanged edges of the top of the surface enclosure. If a sticky residue remains, remove it with an appropriate metal cleaning product.
CAUTION | Do not use isopropyl alcohol or other solvents to |
| clean the HSA. Strong solvents will ruin some |
| finishes. |
HSA 400/402 Series • Installation | HSA 400/402 Series • Installation |