Operations

Unmute an output

Press the UNMUTE button to unmute all video and audio outputs. All of the switcher’s Output LEDs flash on for a second.

Troubleshooting

User’s Guide

If the switcher does not properly respond to IR remote control functions, check the following:

You may be too far from the switcher. The maximum operating range is 30 feet.

You may be too far to the side of the switcher. The remote control must be pointed within 30 degrees of the switcher’s IR sensor for best results.

You may be taking too long to enter the sequence. The unit times out if no command is received in 5 seconds.

The two AAA batteries may be dead. Replace the batteries as shown in figure 1.

The switcher’s front panel security lockout may be on. Toggle the security lockout off. See the appropriate switcher’s manual.

The room lighting may be interfering with the IR signals. Keep the switcher out of bright light.

 

 

Extron Electronics, USA

 

Extron Electronics, Europe

 

Extron Electronics, Asia

 

Extron Electronics, Japan

 

 

1230 South Lewis Street

 

Beeldschermweg 6C

 

135 Joo Seng Road, #04-01

 

Daisan DMJ Building 6F

 

 

Anaheim, CA 92805

 

3821 AH Amersfoort

 

PM Industrial Building

 

3-9-1 Kudan Minami

 

 

USA

 

The Netherlands

 

Singapore 368363

 

Chiyoda-ku, Tokyo 102-0074 Japan

 

 

714.491.1500

 

+31.33.453.4040

 

+65.6383.4400

 

+81.3.3511.7655

www.extron.comIR

 

501Fax 714.491.1517Small Matrix

 

FaxRemote+31.33.453.4050Control

 

FaxOperations+65.6383.4664

 

Fax +81.3.3511.7656

 

 

 

 

IR 501

Small Matrix IR Remote Control

68-873-01 Rev. A

Printed in the USA

10 03

© 2003 Extron Electronics. All rights reserved.

Page 1
Image 1
Extron electronic IR 501 manual Operations, Troubleshooting, Small Matrix IR Remote Control, Unmute an output