Extron electronic MDA 4V HD-SDI and SDI Users Guide Indicators, Specifications, Video

Models: MDA 4V SDI MDA 4V HD-SDI

1 11
Download 11 pages 61.05 Kb
Page 9
Image 9
DISTRIBUTION AMPLIFIER
Figure 10 — MDA 4V HD-SDI and SDI front panels
A Power LED — Indicates power is applied.
B Rate indicators (MDA 4V HD-SDI only) — These indicators light to indicate the detected input video rate on the HD-SDI input BNC connector. The recognized rates are 270 Mbps, 1.485 Gbps, or 2.97 Gbps.
C Unknown rate indicator (MDA 4V HD-SDI only) — When lit, this LED indicates that an input is detected on the HD-SDI input BNC connector but that the MDA did not recognize the rate.

MDA 4V HD-SDI and SDI User's Guide

Indicators

RATE

270 Mbps 1.485 Gbps 2.97 Gbps

UNKNOWN

 

 

MDA 4V HD-SDI

 

 

DISTRIBUTION AMPLIFIER

1

2

3

NThe MDA equalizes and distributes the input regardless of whether the rate is recognized or not.

System operation

After the MDA and all of its connected devices are powered up, the system is fully operational. If any problems are encountered, ensure all cables are routed and connected properly.

Specifications

Video

Gain

Unity

Resolution

8 or 10 bits, automatic

Operation standards

 

MDA 4V HD-SDI

SMPTE-259M

 

SMPTE 292M

 

SMPTE 424M

 

ITU-R BT.601

 

ITU-R BT.1120

MDA 4V SDI

143 Mb/s (4fscNTSC)

 

177 Mb/s (4fscPAL)

 

270 Mb/s (4:2:2 component video)

 

360 Mb/s (4:2:2 widescreen component

 

video), autoselected

Equalization and re-clocking

Automatic for up to -30 dB of cable loss

Auto data rate lock

 

(MDA 4V HD-SDI)

Yes

Video input

Number/signal type

 

MDA 4V HD-SDI

1 SDI, HD-SDI, or 3G-SDI digital

 

component video

MDA 4V SDI

1 SMPTE-259M serial digital component

 

video

Connectors

1 BNC female

Data rates

19 Mbps to 2.97 Gbps

Input cable equalization

Automatic

HD-SDI

120 m (400') using Extron RG6 cable

 

60 m (200') using Extron RG59 cable

SDI

150 m (500') using Extron RG6 cable

 

120 m (400') using Extron RG59 cable

Nominal level

0.8 Vp-p

Minimum/maximum levels

0.5 V to 1 Vp-p with no offset

Impedance

75 ohms

Return loss

 

MDA 4V HD-SDI

<-15 dB @ 5 MHz to 2.97 GHz

MDA 4V SDI

<-15 dB @ 5 MHz to 270 MHz

Maximum DC offset

5 V

Input coupling

AC

10