Extron electronic MLC 104 IP PLUS specifications Specifications, MLC 104 IP Plus Series

Models: MLC 104 IP PLUS

1 4
Download 4 pages 16 Kb
Page 4
Image 4
MLC 104 IP Plus Accessories

MediaLink™ Controllers

MLC 104 IP Plus Series

MLC 104 IP Plus Accessories

Included Accessories

Model DESCRIPTION

 

 

page

PART #

 

EPS 1210 B

 

Extron Desktop Power Supply - 12VDC, 2A.. .

. . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . .

page 694

70-055-01

 

NETXC M-M

 

Male to Male RJ-45 Network Crossover Cable, 6' (1.8 m)

. . . . . . . . . . .

page 418

26-591-01

 

Backlit Button Labels

 

Text Button Labels

. . . . . . . . . . .

n/a

33-954-01

 

Backlit Button Labels

 

Icon Button Labels

. . . . . . . . . . .

n/a

33-955-01

 

MR 200

 

Two-Gang Mud Ring - Black

. . . . . . . . . . .

page 821

70-519-22

 

MR 200

 

Two-Gang Mud Ring - White

. . . . . . . . . . .

page 821

70-519-23

 

Optional Accessories

Model DESCRIPTION

 

 

page

PART #

 

CM-9BLB

 

Nine-Button Control Module - Quad Space AAP

. . . . . . . . . . .

page 394

70-494-02

 

CFG Cable

 

9-pin D Female to 2.5 mm TRS Configuration Cable

. . . . . . . . . . .

page 418

70-335-01

 

IPA T RLY4

 

IP Link® Accessory with Four Relays

. . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . .

page 486

60-545-03

 

IRCM-DV+

 

Dual-Function DVD and VCR IR Control Module

. . . . . . . . . . .

page 393

70-220-02

 

IR Emitter and Shield Kit

 

IR Emitter Kits

. . . . . . . . . . .

page 416

70-283-01

 

MLC IR/RS-232-6'

 

One Projector Communication Cable - Plenum

. . . . . . . . . . .

page 419

26-621-06

 

MLC PW/RS-232/VC-6'

 

One Power, Switcher Communications and MPA Volume Control Cable -

 

 

 

 

 

 

Plenum

. . . . . . . . . . .

page 419

26-626-06

 

MLS 100 A

 

Four Input Stereo Audio MediaLinkSwitcher

. . . . . . . . . . .

page 428

60-497-01

 

MLS 102 VGA

 

Two Input VGA-QXGA and Four Input Stereo Audio MediaLinkSwitcher

page 429

60-497-04

 

MLS 304MA

 

Four Input MediaLinkSwitcher with Mono Audio Amplifier

. . . . . . . . . . .

page 435

60-550-01

 

MPA 122

 

22 Watt Two Channel Integrated MPA - Mini Power Amplifier

. . . . . . . . . . .

page 658

60-668-01

 

SCP 104

 

Secondary Control Panel for MLC 104 IP Plus and System 5 IP

. . . . . . . . . . .

page 397

60-672-02

 

UC50' (50' / 15 m)

 

Universal Projector Control Cable: 9-pin D Female to Bare Wires - 50' (15.2 m). . .

page 419

26-518-01

 

UCM RAAP

 

Universal Controller Mounting Rack Kit - Black

. . . . . . . . . . .

page 410

70-344-02

 

 

SPECIFICATIONS

 

 

General

 

 

 

 

 

Control — host ports

 

 

External power supply

100 VAC to 240 VAC, 50/60 Hz, external, to 12 VDC, 1 A, regulated

 

 

 

 

Power input requirements

 

 

 

 

 

Serial host port

1 bidirectional RS-232 front panel 2.5 mm mini stereo jack

12 VDC, 0.305 A (includes MLC 104 IP Plus and IRCM-DV+)

 

 

MLC 104 IP Plus DV+

 

 

Baud rate and protocol

38400, 8 data bits, 1 stop bit, no parity

 

 

All other models

12 VDC, 0.285 A (0.305 A if used with an optional IRCM-DV+)

 

 

Serial control pin

 

 

 

 

 

 

 

 

NOTE: An MLC 104 IP Plus Series controller must be powered by its own power supply. It cannot be powered by an

 

 

configurations

Mini stereo jack: tip = TX, ring = RX, sleeve = GND

 

 

MLS switcher.

 

 

 

 

 

Ethernet host port

1 RJ-45 female

 

 

 

 

 

 

 

 

 

Temperature/humidity

Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing

 

 

Ethernet data rate

10/100Base-T, half/full duplex with autodetect

 

 

Ethernet protocol

ARP, DHCP, ICMP (ping), TCP/IP, Telnet, HTTP, SMTP

Rack mount

Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing

 

 

Ethernet default settings

Link speed and duplex level = autodetected

No, but wall and furniture mountable

 

 

 

 

IP address = 192.168.254.254

MLC 104 IP Plus DV+

 

 

 

 

Subnet mask = 255.255.0.0

 

 

All other models

Yes, with optional rack mounting kits, and also wall- and furniture-mountable

 

 

 

Default gateway = 0.0.0.0

 

 

Enclosure type

with optional mounting kits

 

 

 

 

DHCP = off

 

 

High-impact plastic

 

 

 

Web server

Up to 200 simultaneous sessions

MLC 104 IP DV+

 

 

 

 

7.25 MB nonvolatile user memory

All other models

Metal

 

 

 

 

Secondary control panel (SCP)

(1) 3.5 mm 5-pole direct insertion captive screw connector

Enclosure dimensions

4.5” H x 4.6” W x 0.1” D (11.4 cm H x 11.7 cm W x 0.3 cm D) (2 gang)

 

 

Program control

Extron’s Global Configurator for Windows®

MLC 104 IP Plus faceplate. .

 

 

 

Extron’s Simple Instruction Set (SIS)

MLC 104 IP Plus AAP and MLC 104 IP Plus DV+

 

 

 

 

Microsoft® Internet Explorer, Telnet

faceplates

4.5” H x 8.2” W x 0.1” D (11.4 cm H x 20.9 cm W x 0.3 cm D) (4 gang)

 

 

IR learning frequencies

30 kHz to 62 kHz

 

 

MLC 104 IP Plus L faceplate 3.15” H x 6.5” W x 0.1” D (8.0 cm H x 16.5 cm W x 0.3 cm D)

 

 

IR learning distance

2” (5.1 cm) to 12” (30.5 cm) from the front panel

MLC 104 IP Plus DV+

2.7” H x 3.4” W x 1.8” D (6.9 cm H x 8.6 cm W x 4.6 cm D) and 2.7” H x 2.6” W

 

 

Control — serial ports

 

 

device

 

 

 

 

 

x 0.9” D (6.9 cm H x 6.6 cm W x 2.3 cm D)

 

 

Display control port

(1) 3.5 mm direct insertion captive screw connector, 3 pole, for bidirectional

 

 

 

 

(Depth excludes knobs and buttons. Fits some 4 gang wall boxes. Allow at least

 

 

Switcher control port

RS-232 control (±5 V)

 

 

 

1.9” [4.8 cm] depth in the wall or furniture.)

 

 

(1) 3.5 mm direct insertion captive screw connector, 3 pole, for bidirectional

All other models device

2.7” H x 3.4” W x 1.8” D (6.9 cm H x 8.6 cm W x 4.6 cm D)

 

 

Baud rate and protocol

RS-232 control (±5 V)

 

 

 

(Depth excludes knob and buttons. Fits some 2 gang boxes.

 

 

 

 

 

 

Allow at least 1.9” [4.8 cm] depth in the wall or furniture.)

 

 

(RS 232)

115200 to 300 baud (9600 baud = default); 8 (default) or 7 data bits;

Product weight

 

 

 

 

 

 

1 (default) or 2 stop bits; no parity (default), or even or odd parity

MLC 104 IP Plus DV+

2.1 lbs (1.0 kg)

 

 

 

Control — IR port

 

 

All other models

1.9 lbs (0.9 kg)

 

 

 

IR control port

(1) 3.5 mm direct insertion captive screw connector, 2 pole

.. . . . . . . . . . . . . . . . .Shipping weight

6 lbs (3 kg)

 

 

 

 

Vibration

ISTA 1A in carton (International Safe Transit Association)

 

 

 

TTL level (0 to 5 V) infrared control up to 1 MHz

 

 

 

Listings

UL, CUL

 

 

 

 

Digital I/O control

 

 

 

 

 

 

 

 

Compliances

CE, FCC Class A, VCCI, AS/NZS, ICES

 

 

 

Number/type

3 digital input/output (configurable)

. .MTBF

30,000 hours

 

 

 

 

Connector

(1) 3.5 mm direct insertion captive screw connector, 4 pole

Warranty

3 years parts and labor

 

 

 

Pin configuration

1, 2, 3 = digital inputs/outputs 1, 2, and 3; GND = GND

NOTE: All nominal levels are at ±10%. Specifications are subject to change without notice.

 

 

Digital inputs

 

 

 

 

 

 

 

 

 

Input voltage range

0-12 VDC

 

 

 

 

 

 

 

 

Input impedance

28k ohms

 

 

 

 

 

 

 

 

Programmable pullup

2k ohms to +5 VDC

 

 

 

 

 

 

 

 

Threshold low to high

>2.8 VDC

 

 

 

 

 

 

 

 

Threshold high to low

<2.0 VDC

 

 

 

 

 

 

 

 

Digital outputs

250 mA sink from 24 VDC, maximum

 

 

 

 

 

384

USA West

USA east

www.extron.com

+1.714.491.1500 / +800.633.9876

+1.919.863.1794 / +800.633.9876

© 2008 Extron Electronics. All rights reserved.

+1.714.491.1517 FAX

+1.919.863.1797 FAX

Pricing and specifications may change without notice.

Page 4
Image 4
Extron electronic MLC 104 IP PLUS specifications Specifications, MLC 104 IP Plus Series, MLC 104 IP Plus Accessories