4-7
MVX Plus 128 VGA A Matrix Switcher • Programmer’s Guide
PRELIMINARY
Command/Response Table for SIS™ Commands
Symbol definitions
] = CR/LF (carriage return/line feed) (hex 0D 0A)
} = Carriage return (no line feed, hex 0D)
(use the pipe character, |, instead for Web browser commands)
• = Space character
| = Pipe (vertical bar) character
E = Escape key (hex 1B)
(use W instead of Esc for Web browsers)
X! = Input number 01 – 12
X@ = Input number (for tie)
00 – 12 (00 = untied)
X# = Output number 01 – 08
X$ = Numeric dB value –18 to +24 (45 steps of gain or attenuation) (Default = 0 dB)
X% = Audio gain 0 – 24 (1 dB/step)
X^ = Audio attenuation 1 – 18 (1 dB/step)
X& = Volume adjustment range 0 – 64 (1 dB/step except for 0-to-1, which is 22 dB)
(default = 64 [0 dB])
See the table on page 4-10.
X* = Room # (for room presets) 10 max. (each can have up to 10 presets (X1@s) assigned)
N A Room is a subset of operator-selected outputs that relate to each other. The MVX Plus switchers support up to 10 rooms, each of which
can consist of from 1 to 16 outputs.
X( = Mute, Lock mode, power supply 0 = off/mode 0/not OK
1 = on/mode 1/OK
2 = mode 2
X1) = Group # (for I/O grouping) 1 through 4 groups (0 = no group)
X1! = Global preset # 00 - 32 maximum (0 = current configuration)
X1@ = Room preset # 10 maximum (0 = current configuration for room)
N A Room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is retrieved from memory,
it becomes the current configuration.
X1# = RGB delay interval Delay in ½ second increments (10 maximum)
X1$ = Video/audio mute: 0 = no mutes
1 = video mute
2 = audio mute
3 = video and audio mute
X1% = Sync frequency xxx.xx (frequency in Hz (V) or kHz (H))
X1^ = Connection status 0 = no input connected
1 = input connected
X1& = Number of inputs 12
X1* = Number of outputs 8
X1( = Part number 68-788-01
X2) = Firmware version number to second decimal place (x.xx)
X2! = Verbose firmware version-description-upload date/time.
See the Query firmware version (verbose) command on page 4-16.
X2@ = Name 12 characters maximum for input names, output names, global preset
names, and room preset names
11 characters maximum for room names
Upper- and lower-case alphanumeric characters and
_ / and spaces are valid.
N The following characters are invalid in the name: {space} ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
X2# = Voltage Positive or negative voltage and magnitude
X2$ = Temperature Degrees Fahrenheit