4-11
MVX Plus 128 VGA A Matrix Switcher • Programmer’s Guide
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional
description
Audio mute commands
Audio mute X#*1Z AmtX#*1]Mute output X# audio
(audio off).
Audio unmute X#*0Z AmtX#*0]Unmute output X# audio
(audio on).
Read audio mute X#ZX(] 1 = mute on, 0 = mute off.
Global audio mute 1*Z Amt1]Mute all audio outputs.
Global audio unmute 0*Z Amt0]Unmute all audio outputs.
Names
Write global preset name EX1!,X2@NG}NmgX1!,X2#]
Example: E1,Security 1NG}Nmg01,Security 1]Name global preset 1
“Security 1”.
Read global preset name EX1!NG} X2@]
Example: E2NG}Security 2]
Write room name EX*,X2@NR}NmrX*,X2@]
Example: E1,Classrm 1NR}Nmr01,Classrm 1]Name room 1 “Classrm 1”.
Read room name EX*NR} X2@}
Write room preset name EX**X1@,X2@NP}NmpX**X1@,X2@]
Example: E1*3,Podium_DVDNP}Nmp01*3,Podium_DVD]Name room1, preset 3
“Podium_DVD”.
Read room preset name EX*,X1@NP}X2@]
N If a preset is unassigned, the X2@ displays [unassigned].
If a global preset is saved, but not yet named, the default name is Preset X1!.
If a room preset is saved, but not yet named, the default name is RmX* PrstX1@.
Write input name EX!,X2@NI}NmiX!,X2@]
Example: E1,Podium camNI}Nmi01,Podium cam]Name input 1 “Podium cam”.
Read input name EX!NI} X2@]
Write output name EX!,X2@NO}NmoX!,X2@}
Example: E1,Main PJ1NO}Nmo01,Main PJ1]Name output 1 “Main PJ1”.
Read output name EX!NO} X2@]