Extron electronic manual Preliminary, Installation, Contents of PMK 450 kit, Route cables

Models: PMK 450

1 2
Download 2 pages 5.71 Kb
Page 1
Image 1
Installation Notes for PMK 450 (70-618-03)
Installation Notes for PMK 450 (70-618-03)

 

 

Front Plate (1)

The Extron PMK 450 Projector

 

Top Plate (1)

 

Pipe Collar (1) with

Mounting Kit can accommodate

 

multiple Extron products of one

 

Set Screws (4)

 

 

eighth, quarter, or half rack sizes

 

 

with power supplies.

 

AC Power Cord

The components of the PMK 450

 

Access Slot

 

 

kit are shown in Figure 1. Also

 

 

included are:

 

Plate

 

 

 

Set-screw hex wrench (1)

Security Screws (2)

Screws (4)

• Security screw hex wrench

 

 

 

 

(1)

 

Rear Plate (1)

• Velcro™ Pads for securing

 

 

 

power supply (2)

 

 

4-40 Screws for mounting

 

 

 

devices (6)

 

 

 

 

Bottom Plate (1)

 

 

 

 

Filler Plate (1)

Installation

Figure 1 — Contents of PMK 450 kit

 

Pipe Collar &

CAUTION Maximum load for the PMK 450 is 15 lb (6.8 kg).

Set Screws

1.

Unscrew the front and rear plates and the security

FRONT

 

 

screws from the sides. Slide the top and bottom

 

 

plates apart. The filler plate is attached to the rear

 

 

plate and should not be removed.

 

2.

Ensure that the mounting pipe is installed with

 

 

the cable access hole facing the rear, away from the

 

 

projector screen.

 

REAR

3.

Loosen the four pipe collar set screws to allow the

Extron PMP

 

top plate to move freely along the pole.

 

 

4. Slide the top plate up the pipe until the pipe collar is

Figure 2 — Mount top plate on pole

 

positioned just above the cable access hole (Figure 2).

Cable Input from

 

Ensure the rear of the top plate is facing to the rear, in

 

Sources (AV control)

 

the same direction as the cable access hole in the pipe.

 

Bottom Plate

5. Level the top plate and secure it by fully tightening

FRONT

 

the set screws. At least three screws must come in

 

 

contact with the pipe.

 

 

6.

Route the cables so that they exit the pipe via the

 

 

cable access hole (Figure 3).

 

Cable Access

7.

Using the supplied 4-40 screws, secure the devices

Hole

 

to the bottom plate. Figure 3 shows the PVS 204

REAR

 

screwed to the plate with a power supply attached by

Cable Output

 

the supplied Velcro pads.

 

 

 

to Projector

 

 

 

8.

Attach cables to the device(s) and pull excess cable

 

 

back into the ceiling. Feed the output cables to the

Figure 3 — Route cables

 

projector via the cable access hole and the bottom of

 

 

 

the pipe.

 

68-1397-01, Rev B

 

 

 

 

 

 

11 07

PMK 450 Projector Mounting Kit • Installation Notes



PRELIMINARY

Page 1
Image 1
Extron electronic manual Preliminary, Installation, Contents of PMK 450 kit, Mount top plate on pole, Route cables