Faber 36 installation instructions Item R in FIGURE, For Ductless Installations

Models: 36

1 14
Download 14 pages 25.95 Kb
Page 7
Image 7
(Item R in FIGURE

5.Level the canopy. The height and level of the canopy can be adjusted by rotating the adjustment screws

(Item R in FIGURE

9) on each side of the blower inside the rangehood

FIGURE 9

6.Connect the Power Supply Cable to the rangehood. At- tach the White lead of the power supply to the White lead of the rangehood with a twist-on type wire connector. Attach the Black lead of the power supply to the Black lead of the rangehood with a twist-on type wire connector. Connect the Green (Green and Yellow) ground wire under the Green grounding screw.

7.Replace the field wiring compartment cover and the grease filters

8.For ducted installations, the damper must be attached to the exhaust opening on the top of the canopy. Connect the ductwork and seal all connections with duct tape.

FOR DUCTLESS INSTALLATIONS

Do not use the damper for ductless installations. The UPPER CHIMNEY COVER must be installed first, before the LOWER CHIMNEY DUCTLESS.

Ductless installations require a Ductless Conversion Kit. This kit consists of a LOWER CHIMNEY DUCTLESS (A in FIGURE 10) with holes for the exhaust air, a DUCTLESS DIVERTER (C), two VENT GRIDS (B) to cover the holes in the chimney cover, and two CHARCOAL FILTERS (D). The DUCTLESS DIVERTER must be installed before the LOWER CHIMNEYDUCTLESS is attached (as indicated bythearrow in FIGURE 10). The LOWER CHIMNEY COVER without holes should be discarded.

FIGURE 10

Once the LOWER CHIMNEY DUCTLESS with holes is installed, the VENT GRIDS (B) are inserted into the holes (FIGURE 11).

FIGURE 11

Attach the CHARCOAL FILTERS to both sides of the blower (as indicated in FIGURE 12). Install the grease filters.

FIGURE 12

9.Install the black chimney clips (K) into the holes located on the left and right of the duct on the top of the body. The chimney must be attached to the body of the rangehood, as indicated in FIGURE 13. The UPPER CHIMNEY COVER

(C) must be installed first, then the LOWER CHIMNEY COVER (B) wraps around it. Both sections are secured to the wall under the CHIMNEY MOUNTING BRACKETS (H). Secure the UPPER CHIMNEY COVER to the MOUNTING BRACKETS with the CHIMNEY SCREWS (J). Secure the LOWER CHIMNEY COVER to the CANOPY (A) by inserting the flanges at the bottom of the LOWER CHIMNEY COVER into the slots on the top of the CANOPY. Insert 2 chimney screws at the bottom of the lower Chimney.

K

FIGURE 13

10.Turn the power supply on. Turn on blower and light. If the rangehood does not operate, check that the circuit breaker is not tripped or the house fuse blown. If the unit still does not operate, disconnect the power supply and check that the wiring connections have been made properly.

Version 04/08 - Page 7