Faber 620000362 manual Dimensional Diagrams, Ducted, Ductless Installations, Rev. 06/08

Models: 620000362

1 2
Download 2 pages 46.27 Kb
Page 2
Image 2
Dimensional Diagrams

Dimensional Diagrams

Ducted

Ductless

26 3/8" - MAX. 37 3/8"

32" - MAX. 38 1/8"

MIN.

MIN.

Pre-Planning Your Installation - Important: Consult the installation instructions before you begin installing this rangehood.

The suggested height to install the hood above the cooktop is 18” . The Orizzonte chimneys are adjustable and designed to meet varying ceiling heights. The chimneys can be adjusted for ceilings between 7' 10 3/16" - 8' 9 3/16" for ducted installations and between 8’ 3 3/16” - 8’ 9 15/16” for ductless installations.

For shorter ceilings, have the chimney cover(s) cut at a sheet metal shop. For higher ceiling installations, the High Ceiling Chimney Kit includes a new 40” upper chimney which would replace the 16 1/8” upper chimney that came with the hood.

Pre-Planning Your Installation - Important: Consult the installation instructions before you begin installing this rangehood.

Make your ductrun as straight and short as possible. The ductrun should not exceed 35 equivalent feet if ducted with the required minimum of 6” round duct. Count 45º angles as 3 feet, 90º elbows as 5 feet, and 90º flat elbows as 12 feet.

For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24” of straight duct between elbows if more than one is used. Do not install two elbows together. If you must elbow right away, do it as far away from the hood’s exhaust opening as possible.

Ductless Installations*

For installations where ductwork is impos- sible or highly impractical, a Ductless Conversion Kit is available. A charcoal filter, which attaches under the blower assembly, absorbs smoke and odors. A ductless diverter assembly directs the air out to a lower chimney with vent grates cut into the sides.

*it is highly recommended that professional style cooking always be vented to the outside.

Rev. 06/08

WARNING! Product specifications are subject to change without notification. Consult the installation instructions before you begin installing this rangehood.

Page 2