Fedders A3DH30B2A Electrical Shock Hazard, Important Grounding Requirements, Use Copper Wire Only

Models: A3DH30B2A

1 16
Download 16 pages 28.15 Kb
Page 3
Image 3
Electrical Shock Hazard

23-23-0360N-003

WARNING

Electrical Shock Hazard

1.Plug unit only into grounded electrical outlet.

2.Do not use an extension cord or plug adaptor with this unit.

3.Do not operate unit with filter removed.

Failure to follow the above precautions could result in electrical shock, fire or personal injury.

If the dehumidifier has a serial plate rating of 115 volts and up to and including 7.5 amps the unit may be on a fuse or circuit breaker with other devices. However, the maximum amps of all devices on that fuse or circuit breaker can not exceed the amps of the fuse or circuit breaker.

Notice

Do not operate this dehumidifier without proper time delay circuit protection. Refer to serial plate for proper power supply requirements.

RECOMMENDED CIRCUIT WIRE SIZES

 

(As installed per building code)

PROTECTOR SIZE

WIRE GAUGE

15 AMP

#14 MINIMUM

20 AMP

#12 MINIMUM

30 AMP

#10 MINIMUM

115V

230V

230V

230V

15A

15A

20A

30A

ELECTRICAL REQUIREMENTS

Notice WARNING

For Your Safety:

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. The fumes can create a fire hazard or explosion.

Power Supply:

115V, 60HZ

 

AC Only 1-Phase

Outlet Requirement:

3-Prong

Grounding Type:

125 V, 15 Amp

Minimum Wire Size:

#14 (A.W.G.) 3-Wire

 

Use Copper Wire Only

Circuit Protector:

15 Amp Time Delay Fuse

 

or Circuit Breaker

Important Grounding Requirements

Your Dehumidifier will operate on any 115 volt, 3-pronged (grounded), 60 Hz circuit. A separate line is not required, but it is advisable not to overload the circuit with heavy duty appliances such as washing machines, etc. For your safety, this dehumidifier is equipped with a 3-pronged, grounding plug and must be plugged into a properly grounded outlet (Figs. 1 & 2). If your outlet is not of the proper type, it is your responsibility to have the outlet and wiring changed to the correct type. DO NOT cut off the third (grounding) prong.

DO NOT USE AN ADAPTER.

1

 

Grounded

 

2

Single outlet

 

 

three-prong

 

 

grounding

 

 

 

 

Three-prong

wall receptacle

 

 

wall receptacle

 

 

 

 

 

 

grounding plug

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Close Windows and Doors

To assure efficient dehumidification, close all windows and doors in the area where the dehumidifier is to operate (Fig.3).

Plug In

Once you have assembled your dehumidifier and installed it in an appropriate location, plug the cord into a properly grounded outlet as indicated in the electrical requirement (Fig. 4).

3

4

1

Page 3
Image 3
Fedders A3DH30B2A Electrical Shock Hazard, Important Grounding Requirements, Electrical Requirements, Use Copper Wire Only