Fedders CH1042CBD1VF Model Specifications, Cooling Performance Data Matched System, Footnotes

Models: CH1048CBD1VF CH1060CBD3VF CH1048CBD3VF CH1060CBD1VF CH1042CBD1VF CH1060CBD4VF CH1048CBD4VF

1 4
Download 4 pages 5.7 Kb
Page 2
Image 2
CH10

CH10

High Efficiency Series

 

 

 

 

 

 

 

 

MODEL SPECIFICATIONS

 

 

 

 

MODEL NUMBER

 

 

CH1018BBD1VF

CH1024BBD1VF

CH1030BDD1VF

 

CH1036BBD1VF

CH1036BBD3VF

CH1036BBD4VF

 

PERFORMANCE DATA

 

 

 

 

 

 

 

 

 

 

NOMINAL COOLING BTU/H

 

17 600

22 600

28 200

 

 

34 000

 

 

NOMINAL HEATING BTU/H

 

17 600

22 000

27 000

 

 

34 400

 

 

SEER (COOLING) BTU/H-W

 

10.0

10.0

10.0

 

 

10.0

 

 

CFM

 

 

600

800

1000

 

 

1250

 

 

VOLTS/HZ/PHASE

 

 

208-230/60/1

208-230/60/1

208-230/60/1

 

208-230/60/1

208-230/60/3

460/60/3

 

VOLTAGE RANGE

 

 

197-253

197-253

197-253

 

197-253

187-253

415-508

 

OPERATING CURRENT AMPS

 

9.2

12.0

15.4

 

18.0

13.2

6.2

 

MIN. WIRE AMPACITY

 

11.3

14.7

18.0

 

22.4

16.5

15.0

 

MAX. HACR BREAKER

 

15

25

30

 

35

25

15

 

COMPRESSOR DATA

 

 

 

 

 

 

 

 

 

 

RLA

 

 

 

8.8

9.8

11.4

 

15.2

11.4

4.8

 

LRA

 

 

 

49

60

75

 

96

75

40

 

FAN DATA

 

 

 

 

 

 

 

 

 

 

 

DIAMETER

 

 

18 INCH / 3 BLADE

18 INCH / 3 BLADE

18 INCH / 3 BLADE

 

 

18 INCH / 4 BLADE

 

 

MOTOR TYPE

 

 

PSC

PSC

PSC

 

 

PSC

 

 

HP (W) / FLA

 

 

1/6

/ 1.0

1/6 / 1.0

1/6 / 1.0

 

1/5

/ 1.8

1/4 / 1.2

 

RPM

 

 

1075

1075

1075

 

 

1075

 

 

CFM

 

 

1800

1800

1800

 

 

2400

 

 

OUTDOOR COIL

 

 

 

 

 

 

 

 

 

 

 

TYPE

 

 

 

 

ENHANCED ALUMINUM PLATE FIN / RIFLED COPPER TUBE

 

 

FACE AREA

 

 

 

9.8

9.8

9.8

 

 

12.0

 

 

O.D. / F.P.I.-ROWS

 

 

5/16 / 18-1

3/8 / 18-1

3/8 / 18-1

 

 

3/8 / 18-1

 

 

REFRIGERANT LINE CONNECTIONS

(SERVICE VALVE

PORT I.D.)

 

 

 

 

 

 

LIQUID

 

 

3/8 ID

3/8 ID

3/8 ID

 

 

3/8 ID

 

 

VAPOR

 

 

3/4 ID

3/4 ID

3/4 ID

 

 

3/4 ID

 

 

WEIGHTS

 

 

 

 

 

 

 

 

 

 

 

NET WEIGHT — lbs.

 

 

137

140

142

 

 

161

 

 

SHIPPING WEIGHT — lbs.

 

143

149

151

 

 

169

 

COOLING PERFORMANCE DATA MATCHED SYSTEM

OUTDOOR

EVAPORATOR

RATINGS AT STANDARD CONDITIONS

 

COOLING DATA AT EXTENDED OUTDOOR AMBIENTS °F.M.B.T.U.H.

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

COIL

BTUH

 

CFM

 

80

85

90

95

100

105

110

115

MODEL*

SEER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CH1018BBD

E3009A

17 600

10

600

TOTAL

18 700

18 300

17 900

17 600

16 700

15 800

14 800

13 900

SENSIBLE

13 500

13 200

12 900

12 700

12 020

11 400

10 700

10 000

 

 

 

 

 

CH1024BBD

E3009A

22 600

10

800

TOTAL

24 500

23 900

23 200

22 600

21 400

20 200

19 000

17 900

SENSIBLE

17 600

17 200

16 700

16 300

15 400

14 500

13 700

12 900

 

 

 

 

 

CH1030BBD

E3612A

28 200

10

1000

TOTAL

29 800

29 300

28 700

28 200

26 600

25 000

23 500

21 900

SENSIBLE

21 500

21 100

20 700

20 300

19 100

18 000

16 900

15 800

 

 

 

 

 

CH1036BBD

E3618A

34 000

10

1250

TOTAL

37 300

36 400

35 500

34 600

31 900

28 800

25 900

23 000

SENSIBLE

26 900

28 400

25 600

24 900

23 000

20 700

18 600

16 600

 

 

 

 

 

CH1042CBD

E6016A

39 500

10

1350

TOTAL

42 400

41 800

41 100

39 500

38 900

37 300

35 800

34 200

SENSIBLE

30 600

30 100

29 600

28 400

28 000

26 900

25 800

24 600

 

 

 

 

 

CH1048CBD

E6026A

46 000

10

1700

TOTAL

49 700

48 500

47 300

46 000

44 400

43 000

41 500

39 800

SENSIBLE

35 800

34 900

34 000

33 100

32 000

31 000

29 900

28 600

 

 

 

 

 

CH1060CBD

E6037A

55 500

10

1850

TOTAL

59 200

57 900

56 700

55 500

54 000

52 600

51 100

49 700

SENSIBLE

42 600

41 700

40 800

40 000

38 900

37 900

36 800

35 800

 

 

 

 

 

*Basic model number only. See unit nomenclature on the last page for exact model number.

FOOTNOTES:

Amps at 104˚F OD temp. 80˚F DB / 67˚F WB indoor temp. Time delay type fuse for HACR Circuit Breaker. For indoor coils nomenclature see indoor coil specification sheet. Air handler includes evaporator coil.

Page 2
Image 2
Fedders CH1042CBD1VF Model Specifications, Cooling Performance Data Matched System, High Efficiency Series, Footnotes