Product Specifications
95% AFUE,
Model Number
Position
FV95A0543A | FV95A0723A | FV95A0905A | FV95A1085A |
|
|
|
|
Electrical Characteristics
Volts | 120 | 120 | 120 | 120 |
|
|
|
|
|
Hertz | 60 | 60 | 60 | 60 |
|
|
|
|
|
Phase | 1 | 1 | 1 | 1 |
|
|
|
|
|
Operating Voltage Range | 102 - 132 | 102 - 132 | 102 - 132 | 102 - 132 |
|
|
|
|
|
Max Fuse or CKT Breakers (Amps) | 15 | 15 | 15 | 15 |
|
|
|
|
|
Minimum Wire Size | 14 | 14 | 14 | 14 |
|
|
|
|
|
Performance Data - Input BTUH |
|
|
|
|
|
|
|
|
|
Low
High
35,100 | 46,800 | 58,500 | 70,200 |
|
|
|
|
54,000 | 72,000 | 90,000 | 108,000 |
|
|
|
|
Performance - Cooling Data
Furnace Cooling Category (Tons)
1.5 - 3
1.5 - 3.5
2.5 - 5
2.5 - 5
AFUE%
| Direct Vent (2 pipe) | Upflow | 95 | 95 | 95 | 95 |
|
|
|
|
|
|
|
|
|
| Direct Vent (2 pipe) | Horizontal / Downflow | 94 | 94 | 94 | 94 |
|
|
|
|
|
|
|
|
|
| Min. Output Capacity |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Direct Vent (2 pipe) - Low | Upflow | 33,345 | 44,460 | 55,575 | 66,690 |
|
|
|
|
|
|
|
|
|
| Direct Vent (2 pipe) - Low | Horizontal / Downflow | 32,994 | 43,992 | 54,990 | 65,988 |
|
|
|
|
|
|
|
|
|
| Direct Vent (2 pipe) - High | Upflow | 51,300 | 68,400 | 85,500 | 102,600 |
|
|
|
|
|
|
|
|
|
| Direct Vent (2 pipe) - High | Horizontal / Downflow | 50,760 | 67,680 | 84,600 | 101,520 |
|
|
|
|
|
|
|
|
|
| Certified Temperature Rise |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Temperature Rise (°F ) | Low | 35 - 65 | 35 - 65 | 35 - 65 | 35 - 65 |
|
|
|
|
|
|
|
|
|
| Temperature Rise (°F ) | High | 35 - 65 | 35 - 65 | 35 - 65 | 35 - 65 |
|
|
|
|
|
|
|
|
|
| Airflow at 0.5" Static |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Airflow CFM Approx | Low Heating ∆T 50°F | 618 | 823 | 1,029 | 1,235 |
|
|
|
|
|
|
|
|
|
| Airflow CFM Approx | High Heating ∆T 50°F | 950 | 1,267 | 1,583 | 1,900 |
|
|
|
|
|
|
|
|
|
| Airflow | Cooling Max | 1,200 | 1,400 | 1,800 | 1,900 |
|
|
|
|
|
|
|
|
|
| Component Data |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Blower Information |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Blower Diameter & Width (Inches) | 11 x 7 | 11 x 7 | 11 x 10 | 11 x 10 |
| |
|
|
|
|
|
|
|
|
| Variable Speed Motor |
| 3/4 hp - ECM | 3/4 hp - ECM | 1 hp - ECM | 3/4 hp - ECM |
|
|
|
|
|
|
|
|
|
| Motor Speed |
| Variable | Variable | Variable | Variable |
|
|
|
|
|
|
|
|
|
| Motor Full Load Amps |
| 7.7 | 9.6 | 12.8 | 9.6 |
|
|
|
|
|
|
|
|
|
| Inducer Draft Blower |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Type |
|
| ||||
|
|
|
|
|
|
|
|
2