Field Controls 24v manual Installation, Good, Better, Best, UV-AIRE Air Purification System, Duct

Models: 24v

1 12
Download 12 pages 42.03 Kb
Page 11
Image 11
Installation
Optional
Location
Supply Air Plenum
Best
Location
A-Coil
Return Air Plenum

UV-AIRE®Air Purification System

Installation

1.Insert the unit downstream from an A-coil in the supply plenum or downstream from the air filter in the return plenum.

Mount base on duct

using the enclosed mounting screws.

2. Insert lamp through hole. Place bracket over end of tube and tighten wing nut.

3. Replace cover on unit and tighten

side screw.

4.Plug into 120V outlet

& place rocker switch in “ON” position.

5.Switch will illuminate & blue glow can be seen through view port when unit is operating properly.

ALWAYS wear protective goggles to shield your eyes from UV damage when installing the UV-Aire.

UV-C can break down plastic material that is not UV resistant. Based on lab tests, positioning the lamp 30 inches or more away from plastic surfaces such as flex duct, drain pans, etc. will prevent any measurable break down.

Installation Options

The UV-Aire can be installed in ducts nine inches and larger. Each unit comes with a duct board mounting kit and a patent- pending angle bracket. A dual lamp model is available for commercial applications and/or increased potency. There is also a model designed specifically for heat pumps and a model for outdoor installations.

Good: Standard Installation

Better: Patented Angled Installation - Single Lamp

16"

Duct

Good

12"

Better

16"

Duct

18"

Best: Two Angled Lamps or Two Lamps Perpendicular

Note: When multiple lamps are used, spacing between lamps should be at least four inches. Angle option allows longer lamps to fit in smaller ducts.

16"

Duct

Best

18"

18"

18"

20"

Duct

18"

11