INSTALLATION OF TEE SECTION
Locate the draft control as near to the furnace or boiler as possible. If the installation has a smokepipe stack control, locate the regulator at least 18" away from the stack control. (See Figures
FOR WOOD FUEL
When burning wood, creosote builds up in the flue pipe. For this reason the tee should be assembled so that the beaded and crimped end is pointed downward. This prevents seepage at the joints. (See Figure 1)
FOR OTHER FUEL | Figure 1 | Figure 2 |
Install tee with beaded and crimped end pointed upward. (See Figure 2)
NOTE: Damper must be mounted with the hinge pins horizontal and the face of the damper plumb for correct operation. This is done by rotating the damper section within the collar for any pipe position. Tighten screw to hold firmly in place.
| Figure 9 |
BEST LOCATIONS FOR OIL OR SOLID FUELS | Figures |
*Selected sizes CSA and UL approved. Not CSA certified for solid fuels.
Page 2