FieldServer FS-8704-14 Driver Related Map Descriptor Parameters Pccc, Timing Parameters

Models: FS-8704-14

1 30
Download 30 pages 51.15 Kb
Page 10
Image 10

FS-8704-14 EtherNet/IP ManualPage 10 of 30

4.4.4 Driver Related Map Descriptor Parameters – PCCC

Column Title

 

 

Function

 

 

Legal Values

 

 

 

 

EIP_Service

 

 

Action to be performed

 

 

Exec_PCCC

(Encapsulation

using

 

 

 

 

 

Allen Bradley PCCC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EIP_Con_Typ

 

 

The type of data transfer required

 

 

Explicit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Any space

delimited numerical

 

EIP_Path*

 

 

Used to stipulate the path to the CPU in certain PLC’s. Paths

 

 

value.

Refer to vendor’s device

 

 

 

vary and are dependent on the structure of the network.

 

 

documentation.

Also

see

 

 

 

 

 

 

 

 

 

 

 

 

 

Appendix A.3, 0 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N Integer

 

 

 

 

 

 

 

 

 

 

F Float

 

 

 

 

 

File_Type

 

 

Allen Bradley file type

 

 

O Output

 

 

 

 

 

 

 

 

B Boolean

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I Input

 

 

 

 

 

 

 

 

 

 

 

S Status

 

 

 

 

 

 

 

 

 

 

 

 

 

File_Number

 

 

Allen Bradley file number

 

 

Any valid numerical value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of data elements to be mapped. If the number of

 

 

 

 

 

 

 

 

 

 

 

data elements exceeds the Map Descriptor length, the list of

 

 

For any given Map Descriptor

 

Length

 

 

data elements will be truncated and an error message will be

 

 

there can be 200 Floats, 400

 

 

 

 

printed once per Map Descriptor. Refer to Appendix C for

 

 

Integers or 800 Bytes

 

 

 

 

 

further information.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Address

 

 

Address in the file

 

 

Any

valid

numerical

value

 

 

 

 

 

between 0 to 255

 

 

 

 

 

 

 

 

 

 

 

 

4.4.5 Timing Parameters

Column Title

Function

Legal Values

Scan_Interval

Rate at which data is polled

≥0.001s

 

 

 

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com

Page 10
Image 10
FieldServer FS-8704-14 instruction manual Driver Related Map Descriptor Parameters Pccc, Timing Parameters

FS-8704-14 specifications

The FieldServer FS-8704-14 is a state-of-the-art communication gateway designed for seamless integration of various devices and protocols within building automation and industrial control systems. This versatile device is equipped with multiple features that cater to the needs of system integrators and end-users alike, making it a popular choice in modern facilities management.

One of the standout features of the FS-8704-14 is its support for a wide variety of communication protocols. This model can bridge the gap between different systems by facilitating communication among protocols such as Modbus RTU, Modbus TCP, BACnet IP, BACnet MSTP, and LonWorks, to name a few. This multi-protocol capability ensures that legacy systems can communicate with newer technologies, providing a future-proof solution for businesses looking to upgrade their infrastructure.

The FS-8704-14 is equipped with 14 configurable input/output points, offering a flexible approach to system design. Users can customize how these points are used, enabling the device to adapt to various application requirements. This configurability extends to both digital and analog inputs, allowing for monitoring and control of a range of sensors and actuators within a building or industrial environment.

In terms of connectivity, the device supports Ethernet, allowing for easy integration into existing networks. The FS-8704-14's robust web interface simplifies configuration and monitoring, making it accessible to users with different levels of technical expertise. This intuitive interface ensures that users can effectively manage the gateway without extensive training.

Another notable characteristic of the FS-8704-14 is its built-in data logging capabilities. This feature enables the collection and analysis of operational data, promoting better decision-making and operational efficiency. Users can access historical data, which aids in predictive maintenance and optimization of system performance.

In summary, the FieldServer FS-8704-14 is a powerful communication gateway that demonstrates exceptional flexibility and compatibility with various automation protocols. Its configurable I/O points, robust web interface, and data logging capabilities make it an essential tool for integrating disparate systems in both building automation and industrial applications. With its comprehensive feature set, the FS-8704-14 helps organizations achieve greater efficiency, reliability, and scalability in their operations.