Firex 242 Hearing Impaired Kit, Technical Specifications, Shipping Specifications, Ordering Data

Models: 242

1 2
Download 2 pages 45.13 Kb
Page 2
Image 2
Smoke Alarm

120V AC Direct Wire

Smoke Alarm

Hearing

Impaired Kit

Smoke Alarm

Strobe

Technical Specifications

4.5"

Mounting

Brackets

 

F

Side

I

Views

R

 

E

4.5"

4.5"

Product Weight

1.3 lbs.

Operating Temperature

40°F to 100°F (4°C to 38°C)

Interconnect Qty.

Up to 6 accessories in addition to 18

 

alarms. This signaling device can be

 

used only with the following FireX

 

smoke, Smoke/CO, and CO alarms: 406

 

(model G-6), 418 (model G-18), 484

 

(model PG-40), 5000 and 4618 (model

 

FADC), 4518 (model ADC), 4418 and

 

1018 (model AD), 4121 (model GC),

 

4480 (model PAD), 12000 (model

 

FADCM), 12400 (model GCM), 10000

 

 

 

 

2.375"

 

 

 

 

 

 

 

 

Shipping Specifications

 

 

 

 

 

 

 

Individual Carton Dimensions

6-5/16" x 5-1/4" x 6-1/2"

Master Carton Quantity

1

 

 

 

 

Master Carton Dimensions

6-5/16" x 5-1/4" x 6-1/2"

Master Carton Weight

1.30 lbs.

 

 

 

 

 

 

 

 

 

 

Ordering Data

 

 

 

 

 

 

 

 

 

 

 

 

Item No.

Kit Includes

Agency Listing

 

Packaging

 

41216 Smoke Alarm-

 

 

 

 

 

242

Model GC, 499 Relay,

UL

 

carton

 

and 240 Strobe

 

 

 

 

 

 

(model COE), 10400 (model COEA).

 

These are low-voltage interconnect

 

alarms with a yellow interconnect wire.

Electrical Rating

120V AC, 60Hz, 264mA max.

 

 

Alarm Point

1.1±0.47%/ft. obscuration

Horn Output

85 decibels at 10 feet

Listing

UL 217

 

 

Detection Type

Ionization

Humidity Range

10% to 93% relative humidity

Installation

This smoke alarm should be installed in accordance with the NFPA’s Standard 72 (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269) and any local codes that apply.

For the AC and AC/DC direct wire smoke alarms, use #18 AWG minimum solid or stranded wire. When interconnecting, maximum wire length between any two is 1,500 feet for #18 AWG or 4,000 feet for #14 AWG (20 OHMS loop resistance).

DO NOT connect to any other type or model of heat or smoke alarm. Connect smoke to a single AC branch circuit. If local codes do not permit, be sure the neutral wire is common to both phases.

 

 

 

 

SMOKE

 

 

 

 

 

 

 

ALARM

 

 

 

 

 

 

 

WHITE

YELLOW

BLACK

 

 

 

 

 

 

 

RELAY

 

 

 

 

 

WHITE

 

WHITE

N.C. (RED)

 

 

 

 

120 V

 

YELLOW

COMMON (GRAY)

 

 

 

 

INPUT

 

 

N.O. (BLUE)

 

 

 

 

BLACK

 

BLACK

 

 

 

 

 

 

191 E. North Avenue

 

 

 

 

 

Carol Stream Illinois 60188 USA

 

 

 

 

WHITE

Customer Service Telephone 1.800.951.5526

3505 Laird Road Unit #14

 

 

 

 

 

 

 

Customer Service Facsimile 1.630.260.7299

Mississauga Ontario L5L 5Y7 Canada

For Technical Service

 

 

 

iccacustomerservice@invensys.com

Customer Service Telephone 1.800.387.7978

Telephone 1.800.445.8299

 

Invensys®, FireX® and Quick Connect™ are

www.FireXsafety.com

Customer Service Facsimile 1.905.828.1265

Facsimile 1.630.260.7243

 

trademarks of Invensys plc., its subsidiaries or

©2007 Invensys Controls

iccacustomerservice@invensys.com

technicalservice@invensys.com

 

affiliated companies.

 

STROBE

WHITE

BLACK

6/07 – 150-1499E

Page 2
Image 2
Firex 242 warranty Hearing Impaired Kit, Technical Specifications, Shipping Specifications, Ordering Data, Installation